Error descriptions are shown on the View Errors Screen.
ERROR DESCRIPTION
ERROR STATE
DISPLAY VOLTAGE HIGH
DISPLAY VOLTAGE GREATER THAN 28 VOLTS FOR 2
SEC.
DISPLAY VOLTAGE LOW
DISPLAY VOLTAGE LOWER THAN 6 VOLTS FOR 2 SEC.
CONTROLLER VOLTAGE HIGH
CONTROLLER VOLTAGE GREATER THAN 28 VOLTS FOR
2 SEC.
CONTROL VOLTAGE LOW
CONTROLLER VOLTAGE LOWER THAN 6 VOLTS FOR 2
SEC.
CONTROLLER SENSOR VOLTAGE
HIGH
CONTROLLER VOLTAGE GREATER THAN 6 VOLTS FOR
2 SEC.
CONTROLLER SENSOR VOLTAGE
LOW
CONTROLLER VOLTAGE LOWER THAN 4 VOLTS FOR 2
SEC.
PROPEL FORWARD OUT OF
RANGE
IS GREATER THAN .3A FOR 2 SEC.
PROPEL REVERSE OUT OF RANGE
IS GREATER THAN .3A FOR 2 SEC.
ELEVATOR TRANSDUCER
VOLTAGE HIGH
VOLTAGE IS ABOVE 4.9 Vdc.
ELEVATOR TRANSDUCER
VOLTAGE LOW
VOLTAGE IS BELOW .1 Vdc
TWO SPEED COIL OUT OF RANGE
OUTPUT CURRENT IS LESS THAN THE COMMAND
CURREENT BY 15mA, OR MORE, WHEN THE COMMAND
CURRENT IS ON FOR 2 SEC.
PARKING BRAKE OUT OF RANGE
OUTPUT CURRENT IS LESS THAN THE COMMAND
CURRENT BY 15mA, OR MORE, WHEN THE COMMAND
CURRENT IS ON FOR 2 SEC.
PROPEL CALIBRATION HIGH
VOLTAGE IS GREATER THAN PROPEL HI CAL FOR 2
SEC.
PROPEL CALIBRATION LOW
VOLTAGE IS LESS THAN PROPEL LO CAL FOR 2 SEC.
PROPEL VOLTAGE HIGH
VOLTAGE IS GREATER THAN 4.9 VOLTS FOR 2 SEC.
PROPEL VOLTAGE LOW
VOLTAGE IS LESS THAN .1 VOLTS FOR 2 SEC.
PROPEL KNOB CALIBRATION HIGH
VOLTAGE IS GREATER THAN PROPEL HI CAL FOR 2
SEC.
PROPEL KNOB CALIBRATION LOW
VOLTAGE IS LESS THAN PROPEL LO CAL FOR 2 SEC.
PROPEL KNOB VOLTAGE HIGH
VOLTAGE IS GREATER THAN 4.9 VOLTS FOR 2 SEC.
PROPEL KNOB VOLTAGE LOW
VOLTAGE IS LESS THAN .1 VOLTS FOR 2 SEC.
START RELAY CURRENT OUT OF
RANGE
OUTPUT CURRENT IS LESS THAN THE COMMAND
CURRENT BY 15mA, OR MORE, WHEN THE COMMAND IS
ON FOR 2 SEC.
REMIX TRANSDUCER VOLTAGE
HIGH
VOLTAGE IS ABOVE 4.9 Vdc.
Summary of Contents for E2850
Page 6: ...This page intentionally left blank...
Page 18: ...This page intentionally left blank...
Page 56: ...This page intentionally left blank...
Page 184: ...This page intentionally left blank...
Page 190: ...This page intentionally left blank...
Page 254: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 62 Schematics HYDRAULIC SCHEMATIC...
Page 255: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 63 Schematics HYDRAULIC SCHEMATIC...
Page 256: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 64 Schematics HYDRAULIC SCHEMATIC...
Page 257: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 65 Schematics HYDRAULIC SCHEMATIC...
Page 258: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 66 Schematics HYDRAULIC SCHEMATIC...
Page 259: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 67 Schematics HYDRAULIC SCHEMATIC...
Page 260: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 68 Schematics HYDRAULIC SCHEMATIC...
Page 261: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 69 Schematics HYDRAULIC SCHEMATIC...
Page 262: ...This page intentionally left blank...
Page 266: ...This page intentionally left blank...