WEILER E2850 REMIXING TRANSFER VEHICLE
4-7
Transporting
4
Towing/Retrieving Machine
Elevator Windrow Valve
(1) Elevator Hopper Baffle Open/Close Spool
(2) Caster Wheel Height Adjustment - Left
(3) Caster Wheel Height Adjustment - Right
(4) Hopper Clean-out Open/Close Spool
(5) Push Roller Extend/Retract Spool
(6) Hopper Dump Raise/Lower Spool
(7) Vibrator Run Spool
Discharge Conveyor Valve
(1) Auxiliary System Pressure Test Port
Pressure should measure 2800 psi.
(2) Generator Run Spool
(3) Rear Steer Spool (Optional)
(4) Conveyor Raise/Lower Spool
(5) Conveyor Lift Pressure Relief
Adjusts the lift pressure of the conveyor lift
cylinder.
NOTICE:
S/N 1001- 1204:
Do not exceed 2500 psi (172 bar). Relief pressure greater than 2500 psi will result in
excessive lift cable forces which may cause cable failure.
S/N 1205 - Up:
Do not exceed 2850 psi (196 bar). Relief pressure greater than 2850 psi will result in
excessive lift cable forces which may cause cable failure.
(6) Conveyor Swing Left/Right Spool
1
2
3
4
5
6
7
1
2 3 4 6
5
Summary of Contents for E2850
Page 6: ...This page intentionally left blank...
Page 18: ...This page intentionally left blank...
Page 56: ...This page intentionally left blank...
Page 184: ...This page intentionally left blank...
Page 190: ...This page intentionally left blank...
Page 254: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 62 Schematics HYDRAULIC SCHEMATIC...
Page 255: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 63 Schematics HYDRAULIC SCHEMATIC...
Page 256: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 64 Schematics HYDRAULIC SCHEMATIC...
Page 257: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 65 Schematics HYDRAULIC SCHEMATIC...
Page 258: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 66 Schematics HYDRAULIC SCHEMATIC...
Page 259: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 67 Schematics HYDRAULIC SCHEMATIC...
Page 260: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 68 Schematics HYDRAULIC SCHEMATIC...
Page 261: ...Schematics C WEILER E2850 REMIXING TRANSFER VEHICLE C 69 Schematics HYDRAULIC SCHEMATIC...
Page 262: ...This page intentionally left blank...
Page 266: ...This page intentionally left blank...