Weil-McLain UO-3 CV Instruction Manual Download Page 4

4

General Information

Section: General Information

Hazard Defi nitions 

Within the boundaries of the hazard warning, there will 
be information presented describing consequences if the 
warning is not heeded and instructions on how to avoid 
the hazard. 

Indicates a hazardous situation, 
which, if not avoided, will result 

in death or serious injury.

Indicates a hazardous situation, 
which, if not avoided, could 

result in death or serious injury.

Indicates a hazardous situation, 
which, if not avoided, could 

result in minor or moderate injury. 

Intended to bring special attention 
to information, but not related to 

personal injury or property damage.

Owner’s Responsibility

Incorrect installation, adjustment, and 

use of this burner could result in severe 

personal injury, death, or substantial 

property damage from fi re, carbon 

monoxide poisoning, soot or explosion.

Contact a professional, quali

fi

 ed service agency for the 

installation, adjustment and service of your oil heating 

system.  This work requires technical training, trade 

experience, licensing or certi

fi

 cation in some states and 

the proper use of special combustion test instruments. 

Please carefully read and comply with the following 

instructions: 

Never store or use gasoline or other 

fl

 ammable 

liquids or vapors near this burner or appliance. 
Never attempt to burn garbage or refuse in this 
appliance.
Never attempt to light the burner/appliance by 
throwing burning material into the appliance. 
Never attempt to burn any fuel not speci

fi

 ed and 

approved for use in this burner.
Never restrict the air inlet openings to the burner or 
the combustion air ventilation openings in the room.

y

y

y

y

y

Please read and understand the manual supplied with 

this equipment. This equipment must be installed, 

adjusted and put into operation only by a quali

fi

 ed 

individual or service agency that is:

Licensed or certi

fi

 ed to install and provide technical 

service to oil heating systems.
Experienced with all applicable codes, standards 
and ordinances.
Responsible for the correct installation and 
commission of this equipment.
Skilled in the adjustment of oil burners using 
combustion test instruments.

The installation must strictly comply with all applicable 

codes, authorities having jurisdiction and the latest 

revision of the National Fire Protection Association 

Standard for the installation of Oil-burning Equipment, 

NFPA 31 (or CSA-B139 and CSA-B140 in Canada).

Regulation by these authorities take precedence over the 

general instructions provided in this installation manual.

y

y

y

y

Incorrect installation, adjustment, and 

use of this burner could result in severe 

personal injury, death, or substantial 

property damage from fi re, carbon 

monoxide poisoning, soot or explosion.

Professional Service   
Required

Frozen Plumbing and 
Water Damage Hazard

If the residence is unattended in severely cold weather, 

burner primary control safety lockout, heating system 

component failures, power outages or other electrical 

system failures could result in frozen plumbing and 

water damage in a matter of hours. For protection, take 

preventive actions such as having a security system 

installed that operates during power outages, senses low 

temperature and initiates an effective action. Consult with 

your heating contractor or a home security agency. 

Summary of Contents for UO-3 CV

Page 1: ...or service work Save this manual for future reference Incorrect installation adjustment or misuse of this burner could result in death severe personal injury or substantial property damage To the Pro...

Page 2: ...2...

Page 3: ...especially during the summer in order to prevent condensation of moisture on the inside surface of the tank y y y y y Remainder of manual to be used ONLY BY QUALIFIED SERVICE TECHNICIANS Weil McLain B...

Page 4: ...t the air inlet openings to the burner or the combustion air ventilation openings in the room y y y y y Please read and understand the manual supplied with this equipment This equipment must be instal...

Page 5: ...3 See Note 2 1 00 NX70LC 1 3 4 0 75 X 60 B Hago 0 75 X 60 B Delavan 175 2 50 UO 4 DV WL6504 See Note 2 1 20 NX90LB 3 1 2 0 85 X 60 W Delavan 0 85 X 60 W Hago 190 4 00 UO 5 DV WL6505 See Note 2 1 40 NX...

Page 6: ...NX90LB 0 40 1 35 6 Slot NX50LC NX70LC NX90LC 1 10 1 75 9 Slot NX50LD NX70LD NX90LD 1 10 1 75 6 Slot NX50LF NX70LF NX90LF Inspect Prepare Installation Site Clearances to Burner and Appliance Provide s...

Page 7: ...ded that an approved insulated stainless steel liner be installed 3 4 5 6 7 For those installations not requiring a chimney such as through the wall vented appliances follow the instructions given by...

Page 8: ...truction sheet supplied with the adapter This kit allows combustion air to be Figure 3 Pressure Switch Installation piped directly to the burner The NX outside air adapter kit may also be used for chi...

Page 9: ...e the bypass plug is NOT installed in the fuel unit Manual bleeding of the fuel unit is required on initial start up If connecting a two pipe fuel supply install the fuel unit bypass plug Oil Leak and...

Page 10: ...rer s wiring diagram prior to connecting the burner wiring All wiring must be in accordance with the latest revision of national Electric Code NFPA 70 and all local codes and regulations In Canada all...

Page 11: ...inals as shown in Figures 7a and 7b Refer to the label on the underside of the control for wiring details Motor off delay on a 7505P will be disabled if the safety and operating limits as shown in Fig...

Page 12: ...on sequence The control will continue to Recycle each time the flame is lost until it reaches a pre set time allotment The control will then go into Hard Lockout instead of recycle This feature preven...

Page 13: ...as the button is held Enables Pump Priming After the reset button has been held for 15 seconds the button can then be clicked during the next ignition sequence to enter Pump Prime mode Run igniter is...

Page 14: ...The fuel valve is opened A flame should be established within the 15 second lockout time LOCKOUT If flame is not sensed by the end of the TFI the control shuts down on safety lockout and must be manu...

Page 15: ...until the retention head engages the fixed stops in the retention ring at the end of the air tube Refer to Figure 10 Tighten the zero setting locking nut The rear door must be closed The adjustment sc...

Page 16: ...Head Retention Head Head Support Legs Head Support Legs Electrode Tips Electrode Tips Electrode Clamp Electrode Clamp Electrode Bracket Electrode Bracket Electrode Insulator Electrode Insulator Elect...

Page 17: ...lint or foreign material Use a clean soft cloth with a degreaser to clean any accumulated soot or oil stains from the throttle cup sight windows Check motor current The amp draw should not exceed the...

Page 18: ...utilizes pressures higher than 100 psig so the actual nozzle flow rate will be greater than the gph stamped on the nozzle body Example A 1 00 gph nozzle 140 psig 1 18 gph For typical nozzle flow rates...

Page 19: ...92 0 99 1 06 0 85 0 95 1 01 1 04 1 13 1 20 0 90 1 01 1 07 1 10 1 19 1 27 1 00 1 12 1 18 1 23 1 32 1 41 1 10 1 23 1 30 1 35 1 46 1 56 1 20 1 34 1 42 1 47 1 59 1 70 1 25 1 39 1 48 1 53 1 65 1 77 1 35 1...

Page 20: ...he splined nut and the lower acorn nut 1 2 3 Turn the air adjustment screw clockwise to adjust the plate with the pointer to the zero position Referring to Figure 10 slide the nozzle line assembly for...

Page 21: ...21 Weil McLain Ultra Oil NX Burner Manual Figure 13 Retention Head Throttle Cup Alignment Figure 14 Blower wheel assembly SK9670 Section Trained Service Technician s Regular Maintenance...

Page 22: ...22 4 22 19 9 17 16 23 10 1 24 6 7 2 15 11a 11c 11b 25 21 26 20 11d 8 5 Section Replacement Parts For best performance specify genuine Beckett replacement parts Replacement Parts...

Page 23: ...et air louvers 1013U 19 Nozzle Line Electrode and Head Assembly Specify 20 PSC Motor Requires Mounting screws 20 x 7 8 21805U 4189 21 Primary control 7505P 22 Retention head assembly 6 slot 51785U 23...

Page 24: ...e choose one of the following options Visit our website at www beckettcorp com warranty Email your request to rwb customer service beckettcorp com Write to R W Beckett Corporation P O Box 1289 Elyria...