Attached List: the relationship among parameters Pr0.08, Pr0.09 and Pr0.10.
Pr0.08
Pr0.09
Pr0.10
Description
0~2
20
—
(no
influence)
—
(no
influence)
Command
Pulse Input
Position
Command
Encoder Resolution
Setting Value of Pr0.08
The process shown above is undergone in terms of the setting
value of Pr0.08, not affected by the settings of Pr0.09 and
Pr0.10.
0
0
0~2
30
Command
Pulse Input
Position
Command
Encoder Resolution
Setting Value of Pr0.10
When the values of Pr0.08 and Pr0.09 are both set as ―0‖, as
shown above, the process is undergone in terms of the setting
value of Pr0.10.
0~2
30
0~2
30
Command
Pulse Input
Position
Command
Setting Value of Pr0.09
Setting Value of Pr0.10
When the value o
f Pr0.08 is ―0‖, but the value of Pr0.09 is not
―0‖, as shown above, the process is underdone in terms of the
setting values of Pr0.09 and Pr0.10.