25
/
61
In the
Calibration Mode
area of the
Calibration
tab, select one method:
Automatic measuring: Click
Auto Measure
. The system carries out fixed calibration
automatically.
The process of automatic fixed calibration is shown below:
Manual calibration: Control the tool to move to the tool sensor surface and click
Z
Manual Set
. The system records the calibration result into the tool offset.
After fixed calibration is finished, control the tool to move to the work piece surface and
execute Z-axis clearing.
3.7.4.2 First-time Calibration/Calibration After Tool Change
First-time calibration/Calibration after tool change operations are used to record tool
differences into the workpiece offset.
The operations are applicable to machine without automatic tool change functions and
need to be executed every time a tool is changed.
Before executing first-time calibration/calibration after tool change operations:
Set the manufacturer parameter
Tool Calibration Type
to
2
.
Control the Z axis to move to the work piece surface and execute clearing to
determine the workpiece origin.
In the
Calibration Mode
area of the
Calibration
tab, select one method:
First-time calibration: Click
First Cali
. The system automatically records the Z-axis
mechanical coordinate of the current point.
Calibration after tool change: Click
Second Cali
. The system automatically
recovers the Z-axis workpiece coordinate of the current point.
First-time calibration process and calibration after tool change process are similar, as
shown below: