1 New Functions
1) New command M802 P458752 is used for clearing the external offset. For detailed
information please refer to chapter 4.4.
2) New command G921 is used for specifying the workpiece coordinates of current point in the
current coordinate system. For detailed introduction please turn to chapter
4.3 ―commands
related to coordinate system and coordinates
‖.
3) New command G922 is used for setting the machine coordinate of the origin of the specified
workpiece coordinate system. For detailed introduction please refer to chapter 4.3
―commands related to coordinate system and coordinates‖.
4) New support for circle, bias and chessboard drilling cycle command (G34, G35, G36, and
G37). For detailed introduction please refer to chapter
4.3 ―special canned cycle‖.
5) New rotation function commands G68/G69, for detailed introduction please refer to chapter
4.3 ―G68/ G69 coordinate system rotation function commands‖.
6) New mirror image function commands G50.1/G51.1, for detailed introduction please refer to
chapter
4.3 ―G50.1/ G51.1 mirror image function commands‖.
7) New command G923 is used for direct tool offset setting, for detailed introduction please
refer to chapter 4.3
―G923 directly set tool offset‖.
8) Strengthened function for command G906 to test if the specified port is timeout. For detailed
introduction please refer to chapter 4.4.
9) New command M903 is used for modifying the current tool number. For detailed introduction
please refer to command M list in chapter 4.4.
10) Command G92 is taken as invalid command in the array machining, and should be deleted
manually. For detailed introduction please refer to chapter 4.3,
―commands related to
coordinate system and coordinates
‖.
11) Refer to chapter 4.4 for new function of naming a subprogram.
12) Improvement of command G904: the usage of PLC address; keywords of PX, PY, PZ are
compatible with PLC address and equal mark expression.
13) Improvement of M901 and G906: the usage of PLC address;
new keywords ―PLC‖ and
―LEVEL‖; and PLC keywords are compatible with [PLC address] and equal mark expression.
14) New command G992 allows the translation of coordinate system. For detailed introduction
please refer
to ―G992 temporarily set WCS according to tool position‖ in chapter 4.3.
15) New command G28 is used for backing to the reference point. For detailed introduction
please refer to chapter 4.3,
―G28 auto back to reference position‖.
16)
New commands related with encoder. For details, refer to ―G codes related with encoder‖ in
chapter 4.3.