64
Control.ini
3
rd
line: If the value of variable 1 is equal 0 (
!vcc1=0
), then
the output 1 to 4 will be cleared (
!ess0000
).
4
th
line: If the value of variable 1 is equal 1 (
!vcc1=1
), then
the output 1 will be activated and output 2 to 4 will be cleared
(
!ess1000
).
5
th
line: If the value of variable 1 is equal 2 (
!vcc1=2
), then
the output 1 and 2 will be activated and output 3 to 4 will be
cleared (
!ess1100
).
6
th
line: If the value of variable 1 is equal 3 (
!vcc1=3
), then
the output 1 to 3 will be activated and output 4 will be cleared
(
!ess1110
).
7
th
line: If the value of variable 1 is equal 4 (
!vcc1=4
), then
the all four outputs will be activated (
!ess1111
).
8
th
line: If the value of variable 1 is equal 4 (
!vcc1=4
), then
the value of variable 1 will be set to zero (
!vmc1=0
).