Control.ini
8.2.4 Project 4 – External control of a VU-meter
display
The project consists of one show, which is triggered by
each contact closure via input 1. Therefore the restart mode is
required.
In show 1 there are four variable decrement commands
(
!vmc-1#
) with a time gap of one second. If LEDs are connected
on the digital outputs, each time the button is activated another
LED is illuminated similar to a VU-meter display. If the button
isn't activated, the variable will be decremented by the variable
commands in the show and the LEDs turn off.
The content of the Control.ini file looks like this:
!i1c!rsr1#
!i1c!vcc1<4!vmc1+1#
!vcc1=0!ess0000#
!vcc1=1!ess1000#
!vcc1=2!ess1100#
!vcc1=3!ess1110#
!vcc1=4!ess1111#
!vcc1=4!vmc1=0#
1
st
line: If input 1 is closed (
!i1c
), then the show 1 (001_
SHOW.WM1) will start in restart mode (
!rsr1
).
2
nd
line: Each time if input 1 is activated (
!i1c
) and the variable
1 is less than 4 (
!vcc1<4
), then the variable increments by one
(
!vmc1+1
).
Summary of Contents for ProCommander AX
Page 1: ...Instruction Manual...
Page 6: ......
Page 33: ...33 ProCommander AX Update...
Page 34: ...34 ProCommander AX Update...
Page 39: ...39 ProCommander AX Update Confirm the alert with OK...
Page 40: ...40 ProCommander AX Update...
Page 42: ...42 ProCommander AX Update...
Page 44: ...44 ProCommander AX Wi Fi Configuration You should see the following...
Page 50: ...50 Analog MIN and MAX value...
Page 52: ...52 Variable...
Page 68: ...68 Folder structure of the Flash Card...
Page 70: ...70 Programming the ProCommander AX...
Page 86: ...86 ProCommander AX Appendix...
Page 88: ...88 Glossary...
Page 90: ...90 ProCommander AX F A Q...