57
Control.ini
The content of the Control.ini file can look like this:
!i1c!ess1001#
!i3o!epf1%20<2.5#
!i4t!epl1_4%50#
!i5c!cfm0<5#
!i5o!cfm32<5#
!tm01:20!rsn:\SHOW\001_SHOW.WM1#
!t&05:00!rsn2#
1
st
line: If input 1 is closed (
!i1c
), the
1 and 4 will be activated (
!ess1001
).
2
nd
line: If input 3 is open (
!i3o
), then PWM output 1 fades
within 2.5 seconds to 20% (
!epf1%20<2.5
).
3
rd
line: With every level change of input 4 (
!i4t
), the PWM
value of outputs 1 to 4 are set to 50% (
!epl1_4%50
).
4
th
line: If input 5 is closed (
!i5c
), the volume fades to level 0
within 5 seconds (
!cfm0<5
).
5
th
line: If input 5 is open (
!i5o
), the volume fades in within 5
seconds to that value which is stored in EE-Prom (
!cfm32<5
).
6
th
line: At 1 minute and 20 seconds after switching on the
device or after insertion of the
card (
!tm01:20
), the
first show starts in normal mode (
!rsn:\SHOW\001_SHOW.
WM1
).
7
th
line: Every 5 minutes (
!t&05:00
) the second show starts
in normal mode (
!rsn2
).
Summary of Contents for ProCommander AX
Page 1: ...Instruction Manual...
Page 6: ......
Page 33: ...33 ProCommander AX Update...
Page 34: ...34 ProCommander AX Update...
Page 39: ...39 ProCommander AX Update Confirm the alert with OK...
Page 40: ...40 ProCommander AX Update...
Page 42: ...42 ProCommander AX Update...
Page 44: ...44 ProCommander AX Wi Fi Configuration You should see the following...
Page 50: ...50 Analog MIN and MAX value...
Page 52: ...52 Variable...
Page 68: ...68 Folder structure of the Flash Card...
Page 70: ...70 Programming the ProCommander AX...
Page 86: ...86 ProCommander AX Appendix...
Page 88: ...88 Glossary...
Page 90: ...90 ProCommander AX F A Q...