8. CALIBRATION

Calibration Settings in the Parameter;

 

F1 off

 

 

tch

 

 

pin

 

 

P1 spd

 

 

P2 cal

 

 

desc

 

 

Cal 

 

 

unload 

 

pass

 

• 

Turn on the scale

• 

Press   

key during self checking, display will 

show

•  Press   key until it displays

• 

Press   

key to confirm display will show

• 

Press     

and    

keys, display will show

• 

Press   

key to show display

• 

Press   

key to enter calibration,

• 

Display will show 

• 

Press   

key until display show

• 

Press   

key into calibration, display will show

• 

When scale get stable, Press   

key,

• 

Display will be show 

• 

Place the test weight on the platform.

• 

After  stable,  press   

key confirm

• 

Display will be show

• 

Then will start self-test and will come to normal display

Note: the unit (kg / lb) is the same as the last displayed one. 

           That is: before you restart the scale to do calibration, if 

you see the unit is kg, then in calibration, the unit is kg; if you 

want to change to lb, you need to press U key to change the unit 

before you restart it.

 

load 

Summary of Contents for WSI-602

Page 1: ...WeighSouth WSI 602...

Page 2: ...1 Power ON OFF pg 8 2 Zero pg 8 3 Tare pg 8 4 Change unit pg 8 5 Hold function pg 9 6 BMI function pg 9 7 Precision 10 pg 9 7 PARAMETER pg 10 8 CALIBRATION pg 11 9 BATTERY OPERATION pg 12 10 MAINTENAN...

Page 3: ...amage to or destruction of the equipment Follow the instructions for use Keep the operating instructions and the declaration of conformity in a safe place Ensure that the scale is standing firmly on a...

Page 4: ...urpose balances with weighing functions and accumulation Mother and child weighing functions BMI with bar graph Wheels at bottom easy to move Rubber mat on the surface of the platform 25 mm LCD with w...

Page 5: ...ture 0 C 40 C 32 F 104 F Power supply external 12V 500mA AC power adapter or 2000mAh Ni MH batteries optional size AA Calibration External Calibration as per Directive 90 384 EEC Class III medical app...

Page 6: ...ing Charging Battery To charge the battery insert the adaptor pin into the jack the jack is locatedon the rear side of the scale The adaptor simply plugs into a standard wall outlet The scale doesn ne...

Page 7: ...socket Turn on the On Off key If you want to turn off press the key again Display will be show the version number and will be starting self checking After self checking display will be come to normal...

Page 8: ...PTION KEY DESCRIPTION Turns the scale power On Off Set to hold mode Set to BMI mode Set pre tare Enter into the menu of parameter Change unit kg lb Sets display to Zero Subtracts weight of container K...

Page 9: ...ator for Zero display TARE Indicator for Tare display Indicator for weighing capacity graph NET Indicator for Net weight GROSS Indicator for Gross weight Lb kg Indicator for weight units Indicator for...

Page 10: ...n set the display of your balance to zero any time by pressing key and therefore ensure that the weighing starts at zero The weight of any container can be tared by pressing key so that with subsequen...

Page 11: ...fter that normal weight display is resumed Pressing while the HOLD function is active will cancel it 6 6 BMI function Press key on the weighing mode display will show the last height xxxxxx use key to...

Page 12: ...on Set the backlight always on Bl off Set the backlight always off Bl au Set the backlight automatic on F5 stu cm Select unit cm inch Select unit inch F6 unit Kg on off Enable disable unit kg Lb on of...

Page 13: ...ress key until display show Press key into calibration display will show When scale get stable Press key Display will be show Place the test weight on the platform After stable press key confirm Displ...

Page 14: ...he main power The scale does not need to be turned on The battery should be charged for 12 hours for full capacity Just under the quantity display is an LED to indicate the status of battery charging...

Page 15: ...ware that problems can be caused by mechanical or electrical influences Check the following Water Corrosive materials Vibrations or temperature or wind Physical damage Check the scale cables for damag...

Page 16: ...6 A D Count out of the range Platform not installed Load cell problem PCB problem 10 3 Determine the Problem Determine whether the problem is in the PCB or the Load Cell Remove power from the system...

Page 17: ...to turn on the scale again Do the calibra tion again or NULL displayed Weight on the platform is below permissible limit Platform not installed cor rectly Power supply faulty Load cell or mechanism fa...

Page 18: ...parameter settings Check the load cell Platform Corner Weight different Shipping screws are not re moved Load cell or mecha nism damaged Check the shipping screws under the platform Use accurate weig...

Page 19: ...return the prod uct to The Manufacturer freight and insurance prepaid for repair replacement or credit at The Manufacturer option Any product repaired or replaced under the foregoing warranty shall be...