Î
Lift the new
retaining ring (Pos. 5) with
the WEH
®
O-ring picker.
Î
Insert the first clamping jaw
segment (Pos. 9) with the
raised side facing the
front seal (Pos. 7).
Î
The retaining ring must be
seated in the recess
provided for it in the
clamping jaw segments.
Î
Now mount the
remaining segments of the
clamping jaws.
Î
Connect the WEH
®
Connector to a test piece a number of times. Visually check the
connector for proper clamping and sealing function and that the clamping jaws
are gripping correctly.
Attention:
During the next pressure test, apply the test pressure to the connector
and media line only gradually.
MD-10015-L51-R1.1.0-03