7�2
Installing the media line
Please note:
Subsequent mentions of descriptions and position numbers refer to
Chapter 3. Product overview / product description on page 10
.
Î
Unscrew the protection cap from the port.
Î
When mounting media hose line, hold an open-ended
spanner against the spanner flat A/F(1) (
Figure 1
).
Î
Screw the ‘B1’ media inlet pressure-tight to the port for the
media line (
Figure 1
).
Tightening torque 10 Nm ± 2 Nm (G1/8“ female thread).
7�3
Checking the connection for leak tightness
Î
Connect the connector to a closed test piece.
Î
Slowly apply the operating pressure to the connector and media line.
Caution:
The test piece must be closed.
Î
Check the connector, the connection to the media line and the connection to the test
piece for leak tightness.
Attention:
Do not use a leak detection spray that contains ammonia, since this could
cause corrosion of the connector.
Figure 1
A/F(1)
B1
MD-10015-L51-R1.1.0-03
Page 16
Operating instructions
AE