25
Wegaconcept
User manual
ENGLISH
16
Checks and cleaning
16.1
Checks and maintenance
To ensure perfect safety and effi
ciency of the
machine over time, it is necessary to carry out
maintenance. In particular,
it is advisable to ask the
Technical Service to carry out an overall check of
the machine at least once a year.
Checks
D
aily
W
eekly
Monthly
MACHINE
Using the machine's display, check that the
•
pump pressure indicated is around 8-9 bar.
Check that the boiler pressure indicated on
•
the display is consistent with a programming
value.
In case of anomalies, contact the Technical
•
Support Service.
X
PORTAFILTER FILTERS
Check the wear of the fi lters, if there is dam-
•
age to the edges and check if coff ee grounds
are getting into the cup. If necessary replace
the fi lters.
X
GRINDER-DOSER
Check the dose of the ground coff ee, which
•
should be about 6-7 gr. at a time, and adjust
the amount as necessary.
Check the degree of grinding and modify as
•
required.
Check the grinders for wear: they should be
•
replaced if there is too much powder in the
ground coff ee.
X
SOFTENER
Carry out regeneration of the softener (for the
•
manual softener).
Check that there is salt in the container (for the
•
softener in the automatic version).
X
16.2
Cleaning
For perfect hygiene and effi
ciency of the unit, a
few simple cleaning tasks are required.
The indications given here are applicable for
normal use of the coff ee machine. If the machine is
used intensively, then cleaning should be performed
more frequently. When cleaning, always use cloths
that are completely clean and hygienic.
Cleaning
D
aily
W
eekly
Monthly
CAPPUCCINO MAKER
Clean several times a day as indicated in par.
14.2, especially if used continuously.
XXX
FILTERS and PORTAFILTERS
Use a screwdriver to detach the fi lter from the
portafi lter.
Clean the inside of the portafi lter with a brush and
wash the fi lter and portafi lter with hot water.
Failure to clean the fi lters and portafi lters will
compromise the quality of the coff ee and also
cause problems such as bad extraction and cof-
fee grounds at the bottom of the cup.
X
STEAM NOZZLE / AUTOSTEAMER
Keep the nozzle clean at all times using a cloth
dampened in lukewarm water.
X
STEAM NOZZLE / AUTOSTEAMER TERMINALS
Check and clean the tips of the nozzle, clearing
out the steam outlet holes with a small needle.
X
BODY
Clean the panels of the body with a cloth
dampened in lukewarm water. Do not use abra-
sive detergents which may scratch the surface
of the body.
X
PERFORATED DISK and
CONTAINMENT RING
Loosen the screw (
A
)
and Remove the
perforated disk (
B
)
and the containment
ring (
C
) from the
dispensing group.
Wash with hot water.
X
C
B
A