14
Wegaconcept
User manual
9.2
Programming hot water doses
To program the hot water doses, proceed as fol-
lows:
place the cup under
•
the hot water nozzle
(
12
);
press and hold down
•
the "
PROG/STOP
"
key
on the left push-but-
ton panel until all dose
key LEDs switch on;
press the hot water delivery key
•
;
when the desired dose has been reached, confi rm
•
by pressing the hot water key
again;
repeat the operation for the other dose button;
•
upon completion of programming, press the
•
“
PROG/STOP
” key
.
12
9
Programming
doses
9.1
Programming coff ee doses
To program the dose keys, proceed as follows:
press and hold the “
•
PROG/STOP
” key down for
5 seconds: the LED of the “
PROG/STOP
” key will
fl ash and all keys on the push-button panel being
programmed will turn on;
fi ll the fi lter with a dose of ground coff ee and
•
press it with the coff ee press;
attach the portafi lter to the delivery group;
•
put the coff ee cup under the dispensing spout
•
(
16
);
press the desired dose
•
key (e.g.: “
1 Espresso”
);
wait for delivery;
•
to confi rm the desired
•
dose press again the
dose key or the "
PROG/
STOP
" key;
once the dose is confi rmed, the LED of the pro-
•
grammed key switches off and only the keys yet
to be set remain on;
repeat this operation for the other dose but-
•
tons;
upon completion of programming, press the
•
“
PROG/STOP
” key to exit dose programming.
16
i
After 30 seconds of idle time, the machine
will automatically exit the dose programming
mode, confirming the already programmed
ones.
i
All models are provided with 2 keys for the
dispensing of hot water. These can be pro-
grammed individually and supply doses which
are independent from one another.
i
The 4GR version has 2 hot water nozzles. The
left key controls the left hot water nozzle,
while the right key controls the right hot water
nozzle.
i
The programming of each dose must be carried
out with ground coff ee and not with previously
used coff ee grounds.
i
It is possible to program all the push-button
panels of the machine simultaneously using
only the left push-button panel. To obtain dif-
ferent doses for the various groups, perform the
programming by starting with the left push-
button panel and then all the others.