12.
Service checks and intervals
Figure 19
–
50 hours before maintenance
Figure 20
–
Maintenance due
The PLC screen will let you know 50 hours before the first
major maintenance of the unit, as depicted on Figure 19.
Once the maintenance is due, Figure 20 will show.
BEFORE BEGINNING ANY WORK ENSURE THE
WEEDINGTECH M1200 HAS BEEN SWITCHED OFF,
AND THE ELECTRICAL SUPPLY FROM THE
GENERATOR IS DISCONNECTED.
EVERY 250 HOURS (6 MONTHS MAXIMUM)
•
Change generator oil
•
Check boiler flue gas for CO content,
adjust air flap setting if required
•
Check and de-scale coil (if necessary)
•
Change particulates filter cartridge (if applicable)
EVERY 500 HOURS (12 MONTHS MAXIMUM)
•
Change generator oil filter
•
Change generator air filter
•
Check and adjust and clean generator injectors
•
Check and adjust and clean generator valve and
rocker head clearance
•
Change fuel filter.
•
Check and clean boiler mixing device.
Replace electrodes and nozzles if
necessary
•
Check and adjust boiler burner pressure regulator
setting
•
Check and clean boiler burner chamber
•
Check electrical control panel for moisture damage
•
Check and adjust boiler pump oil pressure and level
•
Change particulates filter cartridge (if applicable)
EVERY 750 HOURS (OR 18 MONTHS MAXIMUM)
•
Change pump oil and filter cartridge (if applicable)