Basic fault finding
The PLC of the M1200 is designed to help the user in case
something goes wrong.
Figure 18
–
Summary screen of the PLC
Num.
Description
1
Boiler incoming water temperature
2
Boiler outgoing water temperature
3
Foamstream tank level sensor
4
Water tank level sensor
5
Diesel level sensor
6
Boiler controller
7
Water pump
8
Venturi
9
Lance solenoid valve
10
Lance flow switch
11
Lance pressure switch
12
Boiler diesel pump
13
Return to tank flow switch
Green colour indicates that the sensor is seeing a signal and
grey or red
that it doesn’t. Red colour does not necessarily
mean that there is an issue with the sensor. Normal sensor
states during start-up/shut-down and normal operation are
described in the table below.
Num.
Start-up
Running
1
Not applicable
2
Not applicable
3
Green
Green
4
Green
Green
5
Green
Green
6
Should be visible
7
Green
Green
8
Grey
Green
9
Grey
Green
10
Green
Green
11
Grey
Green
12
Green
Green
13
Green
Grey
When a fault occurs, a fault message will be displayed in the
box n
o
4 of Figure 14. Below are the faults that can appear
in that screen and what they mean.
1
2
3
4
5
6
7
8
9
10
11
12
13