5.
Pre-start checks
THESE CHECKS MUST BE COMPLETED BEFORE EACH
START OF THE M1200. ANY FAULTS MUST BE RECTIFIED
BEFORE THE M1200 IS SWITCHED ON.
✓
The M1200 water tank is securely attached to the
transport vehicle
✓
The M1200 is in good condition and panels are
closed
✓
There are no signs of leaks from any pipe or
connection
✓
Pipe routes are clear of sharp edges and hot
surfaces
✓
Air intakes are clear of debris
✓
Generator and boiler exhaust are secure and clear of
debris and obstruction
✓
Water tank is full of clean water
✓
Water filter is clean and free from debris
✓
Water feed valve is connected and in the
‘
on
’
(inline)
position
✓
The water return pipe and water level sensor is
connected
✓
Air has been bled from water system (see section 7)
✓
Fuel tank is full of clean diesel fuel (derv or gasoil)
✓
Boiler fuel filter is clean and free from debris
✓
Foamstream® concentrate tank is full of
Foamstream® concentrate
✓
Foamstream® filter is clean and free from debris
✓
The consumable has not been subject to
temperatures below 5°C and frozen or separated
✓
Vent screw on Foamstream® tank filler cap is open
✓
Generator engine oil level is correct
✓
Pump oil level is correct
✓
The lance, hose reel and hose are securely
connected and free from damage
✓
Lance wear pads are not excessively worn