WELD THE WORLD
Cod. 006.0001.1960
03/05/2019 V.2.2
Discovery 172T
19
ENGLISH
8.2 MMA WELDING - SECOND LEVEL MENU
SYN
L1
L2
L3
L15
L13
L14
L10 L11
L12
L29 L28
D1
S1
S2
E1
L6
S3
S4
S5
S6
L9
L8
L4
L5
L7
L33
L31
L32
L30
L26 L27
L18
L22
L20
L21
L23
L24
L25
L17
L16
L19
EL.
A
3 sec ACTIVA-
TION/SELECTION
B
SETTING
A
○ Hold down the
S2
button for 3 seconds to access the 2nd level menu.
The LED will illuminate.
○
Use the
encoder E1
to scroll the list of settings to be edited.
The acronym relative to the selected setting is shown on display
D1.
○
Press the
S3
button to confirm.
The value relative to the selected setting appears on display
D1.
B
○
Using the
encoder E1
, edit the value of the selected setting.
Tab. 4 - Parameters of the 2nd level menu: MMA mode
ACRONYM / LED
SETTING
MIN
DEFAULT
MAX
NOTES
EL.
ELECTRODE TYPE
-
bAS
-
bAS= basic
rUt= rutile
Crn=
chromium/
nickel
ALU= aluminium
Urd
VRD (OUTPUT VOLTAGE REDUCTION)
oFF
oFF
On
*4
U.EL.
LONG ARC VOLTAGE MMA
37
SYn
65
*2
rC
REMOTE CONTROL ACTIVATION
oFF
oFF
On
*3
Press any key
(
except S3
) to save the setting and quit the menu.
*2: SYN:
This code indicates that parameters control is synergic. The optimal value of this param
-
eter is set automatically by the microprocessor on the basis of the preset welding current value.
This value can be displayed but it is not user-adjustable.
When
SYN
is installed, to display the synergic value press the following button:
S1
Summary of Contents for Discovery 172T
Page 1: ...Cod 006 0001 1960 03 05 2019 V 2 2 Discovery 172T Instruction manual ENG...
Page 2: ...WELD THE WORLD Cod 006 0001 1960 03 05 2019 V 2 2 Discovery 172T 2 ENGLISH...
Page 50: ...WELD THE WORLD Cod 006 0001 1960 03 05 2019 V 2 2 Discovery 172T 50 ENGLISH 13 WIRING DIAGRAM...
Page 55: ...WELD THE WORLD Cod 006 0001 1960 03 05 2019 V 2 2 Discovery 172T 55 ENGLISH...