9 | Maintenance

6 / 10

2112899A OI Ti22 ProX

l

Add a sufficient amount of glycol to get a water/glycol mix
ratio of 25 % to 40 % glycol.

l

Check the sea water and chilled water circuit for leaks in
the entire system and from the sea-cock to the sea water
outlet.

l

Check the condensate outflow from the condensed-water
tray and the condensed-water drain line for free passage
and leaks.

l

Check the functioning of the system. Run the Ti22 ProX in
cooling and heating mode for at least 10 minutes. Let the
compressor start 3 to 4 times in each mode.

Check yearly:

l

Check the entire sea water circuit, including the condenser.
The time interval may need to be increased, depending on
the degree of biological fouling (by shellfish etc.). Soiling of
the sea water circuit reduces the sea water flow rate, which
decreases the heat dissipation and may result in high-pres-
sure switch-offs. If the condenser is soiled, the cooling or
heating capacity of the system decreases. An expert must
clean the sea water circuit (such as the installer or your
Webasto Service Centre).

l

Check the electrical connections for corrosion of the con-
tacts and for firm seating.

l

Check the heater exhaust system for corrosion and leaks, if
a fuel operated heater is installed.

l

Check the fuel line for leaks. Clean or replace the fuel filter,
if a fuel operated heater is installed.

Winter storage:

l

Make sure the cooling water circuit contains at least 25 %
to 40 % glycol to prevent accidental freezing of the system
during winter. For sufficient protection, let the glycol per-
centage depend on the local temperature.

l

Empty the entire sea water circuit and close the sea water
valve.

General Recommendation:

l

When leaving the boat unattended for a longer period
close all sea-water valves.

Summary of Contents for Ti22 ProX

Page 1: ...Operating Instructions Chilled Water Marine Air Conditioning Systems Ti22 ProX English...

Page 2: ...ting 3 1 4 Warranty and liability 3 1 5 Measurements 3 2 Safety 3 2 1 Intended use 3 3 General 3 4 Home screen and icons 3 5 Standby 4 6 ON OFF 4 7 Operation 4 7 1 Selecting the setpoint temperature 4...

Page 3: ...cooling on ships The Ti22 ProX meets the current state of technology and recog nized safety rules WARNING Improper or inappropriate use may result in danger to life and limb of the user and others as...

Page 4: ...ed Depending on the installation location this may also be the temperature of another cabin After approx 20 seconds the base colour of the control ele ment changes to indicate the operating mode cooli...

Page 5: ...need to connect a cabin temperature sensor 8 System settings The explanation of the Timer function is an example for the op erating logic The explanation also applies to other setting levels or funct...

Page 6: ...ter flow rate which decreases the heat dissipation and may result in high pres sure switch offs If the condenser is soiled the cooling or heating capacity of the system decreases An expert must clean...

Page 7: ...no intake Check the flow rate of the seawater circuit at the seawater outlet The difference between evaporator in let and outlet temperature must be approxim ately 5 K At se water temperature 6 C no h...

Page 8: ...the control ele ment At least one compressor must be set as active See Setting level 3 parameter menu Init data communica tion 17x flashing pause Data communication Electrical wiring de fective Power...

Page 9: ...ect to interference or display values falsi fied Check whether the temperature sensor is subject to direct fault sources such as direct sunlight or devices radi ating heat Replace defective sensor The...

Page 10: ...country can be found in the Webasto ser vice centre leaflet or the website of the respective Webasto representative of your country www webasto com 2112899A Europe Asia Pacific Webasto Thermo Comfort...

Reviews: