Automatic sauna splash system, Sauna Plus 8
Index: 05 Change date: 11.09.2018
Operating instructions no.: BA DW 003-05 Sauna Plus 8 EN 24+230V.docx
Page 65 of 76
Fault table
Fault indication / fault
Possible cause
Actions
Fault indication 1
Fault pressure switch, short-
circuit
Pressure switch defective
Splash line blocked
Check pressure switch, replace if
necessary
Check / exchange splash line
Fault indication 2
Water inlet pressure of 1.2barg
not reached. safety switch-off
fragrance
Water supply interrupted
Water pressure too low
Check water supply
Check the supply line
Fault indication 3
Pressure drop, 1.2barg not
reached during the splash,
safety switch-off fragrance
Water supply interrupted
Water pressure too low
Check water supply
Check the supply line
Fault indication 4
no response
Communication fault
between display board and
control board
Switch off the device at the main
switch and switch it on after 5
seconds
The device cannot be switched on
Main fuse F0 defective
Main switch defective
Power supply interrupted
Check or exchange the fuse
Check main switch
Check the power supply
System does not work
Wrong setting
Main fuse F1 at main PC
board defective
Check settings
Exchange main switch F1
Effect illumination does not work
Fuse F3 effect illumination
defective
Wrong setting
Exchange fuse F3
Check settings
Announcement does not work
Fuse F4 for announcement
defective
Wrong setting
Exchange fuse F4
Check setting
Solenoid valve without function
Fuse F5 solenoid valve water
defective
Solenoid valve defective
Exchange fuse F5
Check / renew solenoid valve
1 dosing pump without function
Fuse F10, F11, F12 or F13
defective
Motor of pump defective
Exchange appropriate fuse
Check / renew motor of pump
Button illumination does not work
Fuse F14 defective
Exchange fuse F14
No splash
Fuse F5 defective
Solenoid valve defective
No water supply pressure
Device input filter clogged
Splash line blocked
Check fuses
Check / exchange solenoid valve
Check water supply
Clean input filter
Clean splash line