Automatic sauna splash system, Sauna Plus 8
Index: 05 Change date: 11.09.2018
Operating instructions no.: BA DW 003-05 Sauna Plus 8 EN 24+230V.docx
Page 20 of 76
To b) The line cannot self-drain
DANGER !
An additional system separation unit for nonpoisonous liquids
without free drainage according to DIN EN 1717 (in Germany and
the EU) must be installed when the splash line is not self-draining
(e.g. installed with incline, or water trap in the line). This ensures
that no fragrance can be sucked back into the drinking water line!
(see Section 3.1 Delivery scope / accessories)
Use a pipe or hose with a maximum internal diameter of 6mm.
Connect the splash line 3/8" internal thread to the wall feed-through (optional)
3/8“ external thread. Screw the heater shower hand-tight to the wall feed-
through. Only use Teflon tape for sealing to make shower cleaning as easy as
possible.
The optional sauna splash connection set, from Company WDT, is used to connect
the automatic sauna splash system with a hose to the wall feed-through.
4.5
Electrical installation
DANGER DUE TO HIGH VOLTAGE !
The electrical installation may only be performed by appropriately
trained specialist staff!
The automatic sauna splash system must be switched to a voltage-
free state and secured against switching on before electrical work is
performed!
Connect the ground terminal (11) with the ground wire on site.
Connecting control signals to external consumers:
The standard version provides 5 control signals for controlling external consumers.
Connect the appropriate control signals to the corresponding consumers.
See
Section 3.2.2,
Control unit
and Section 9.2, Terminal plan.