Automatic sauna splash system, Sauna Plus 8
Index: 05 Change date: 11.09.2018
Operating instructions no.: BA DW 003-05 Sauna Plus 8 EN 24+230V.docx
Page 61 of 76
7
Maintenance, service, faults
7.1
Device maintenance
It is recommended to task a specialist company with maintenance.
The following points must be considered for problem-free function of the
automatic sauna splash system:
1.
Regular cleaning of the device.
2.
Storage of the consumables
3.
Inspection and maintenance according to the maintenance protocol in
Section
9.5
Check the dosing valve
Some fragrance concentrates create deposits in the dosing line and the dosing
valve. It is possible that water is pressed back during the splash or that the fragrance
dosing is interrupted, in particular when the dosing hose is already damaged.
Therefore check the dosing valve every 6 months or as required. Let the pump
aspire a bit of air and track the air bubble while the pump is running when you top
up the fragment. The fragrance dosing system is in order when the air bubble is
transported in the suction/pressure hose. The dosing valve is clogged when the air
bubble only moves back and forth. Disconnect the dosing hose from the dosing
valve for cleaning purposes, unscrew the dosing valve and wash it with warm water
or methylated spirits. Install a new valve when this is not successful.
Check / replace hose set
The pump hose in the pump is
subject to mechanical and
chemical stress. The pump hose
must therefore be checked
during each fragrance change in
order to detect damage and
replace the hose set in due time.
The hose set must be exchanged
at the latest every 6 months and
more often when corrosive
fragrances are used!
Figure 19, Hose dosing pump
32
35
34
33
41
42