ANGEL™ 4
• SEMI 4 with SENSi™ Activated
· This mode is Semi-Auto and has a
longer
cycle time resulting in more
sustainable
rates of fire.
This SEMI Mode works on the following principles:
· Should a ball be detected within the window of opportunity, the ANGEL™ will fire in
response to a trigger pull.
· Should a ball not be detected within the window of opportunity, a small delay will
be added and the ANGEL™ will fire after this delay irrespective of whether a not a
paintball is present.
· This Mode carries a risk of chopping a paintball, but negates the need for a release
and re-pull of the trigger to initiate the next shot.
• AUTO
Full Auto to a max of13/sec.
• 3 SHOT
3 shot burst variable rate to max of 13/sec.
• AUTO
Full Auto to a max 13/sec.
• PROG 1 TO 5
Programmable mode via IR Link, with a max rate of 13/sec.
DWELL FEATURE
This controls the valve opening time. Longer Dwell times use more gas and generates
more noise but allows the marker a greater tolerance to paint, temperature and
pressure variables. Shorter Dwell times use less gas and reduce noise but are less
tolerant of poor paint and pressure variables. Adjustment is only recommended if you
wish to fine-tune your marker to specific accessories.
CYCLES FEATURE
This is the ANGEL™ equivalent of a milometer and will register the total shot count that
the ANGEL™ has fired.
ID FEATURE
This is a unique serial number identification that is factory set.
TRIGGER OFFSET FEATURE
This allows the user to set the trigger snubber and can be used to ensure that trigger
bounce is reduced on triggers that have been set with a very short pull. It should be
used to eliminate trigger bounce and not used to induce trigger bounce. It is the user’s
responsibility to ensure that the setting they have selected does not cause accidental
discharges. Level 1 - Minimum Trigger Damping, Level 20 - Maximum Trigger Damping.
FEATURE
MENU
EXTERNALLY
EXTERNALLY
PARAMETER
ALLOCATION
VIEWABLE
ADJUSTABLE
MENU
ADVANCED & BASIC
YES
YES
Basic/Advanced
FETCH
ADVANCED & BASIC
YES
YES
ON/OFF
TIMER
ADVANCED & BASIC
YES
YES
0.5-30min
A1
ADVANCED & BASIC
YES
YES
0.5-30min
A2
ADVANCED & BASIC
YES
YES
0.5-30min
A3
ADVANCED & BASIC
YES
YES
0.5-30min
SENSi™ TEST
ADVANCED & BASIC
YES
YES
Pass/Fail
MROF
ADVANCED
YES
YES
8-25bps
Hopper T Time
ADVANCED
YES
YES
0.01-1.0 Secs
Hopper A Time
ADVANCED
YES
YES
1-4 Shots
TEMP
ADVANCED
YES
YES
°C / °F
VIBRATOR
ADVANCED
YES
YES
ON/OFF
TRIP
ADVANCED
YES
YES
Re-Zero
BACKLIGHT
ADVANCED
YES
YES
ON/OFF
SEND
ADVANCED
YES
YES
ON/OFF
ROF
ADVANCED
YES
YES
Re-Zero
MODE
ADVANCED
YES
NO
Where Applicable
DWELL
ADVANCED
YES
NO
9-20m/s
TRIGGER OFFSET
ADVANCED
YES
NO
1-20 Levels
CYCLES
ADVANCED
YES
NO
Non-Resetable
ID
ADVANCED
YES
NO
Non-Resetable
DUAL EXTERNAL LCD MENUS IN SAFE
–
ADVANCED MENU CONTINUED
• Never adjust your trigger offset sofinely that accidental discharge may occur
due to shock loads or vibrations.
m
WARNING
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES