ELECTRICAL SAFETY

•  Turn OFF the power supply before connecting the device.

•  Unconnected wires must be cut at different lengths and insulated singularly.

•  Do not stretch the cable. Do not pull or carry by cable. Do not use the cable as a handle.

•  In compliance with 2004/108/EC norm on electromagnetic compatibility, following precautions 

must be taken:

•  Before handling and installing the equipment, discharge electrostatic charges from your body 

and tools which may come in touch with the device.

•  Power supply must be stabilized without electronic noise. Install EMC filters on device power 

supply if needed.

•  Always use shielded cables (twisted pair cables whenever possible) and avoid cables longer 

than necessary.

•  Avoid placing the signal cable near high voltage power cables.

•  Mount the device as far as possible from any capacitive or inductive noise source. Shield the 

device from electronic noise source if needed.

•  To guarantee a correct working of the device, avoid using strong magnets on or near by the 

unit.

•  Minimize electronic noise by connecting the cable shield and/or the connector housing and/or 

the sensor to ground. Make sure that ground is not affected by electronic noise.

ELECTRICAL CONNECTION

Signals 0...20 mA

Signals 0...10 V

cable output connector output

0 VDC Power Supply

BK

1

13...30 VDC

RD

2

0 VDC analog

YE

3

START

BU

4

+I out

+V out

GN

5

STOP

OG

6

not connected

WH

7

FAULT

not connected

GY

8

Shielding

Shield

Case

Cable specifications

Type

HI-FLEX M8

Wires

2 x 0.22 mm

+ 6 x 0.14 mm

2

 

Shield

Tinned copper braid

External Ø

5.3 up to 5.6 mm

Impedance

<90 Ω/Km (0.22 mm

2

), <148 Ω/Km (0.14 mm

2

)

Min. bend radius ≥ 25 mm

1

2

5

4

3

7

6

8

connector output, 

M12, male

Summary of Contents for MXAX SERIES

Page 1: ...rposes other than those for which it has been designed could result in serious personal and or environment damages High current voltage and moving mechanical parts can cause serious or fatal injury Wa...

Page 2: ...nstructions The arrow indicates the standard counting direction count up information Recommended minimum bend radius of the cable R 25 mm Overall dimensions Mounting direction Mounting direction M4x25...

Page 3: ...gnal cable near high voltage power cables Mount the device as far as possible from any capacitive or inductive noise source Shield the device from electronic noise source if needed To guarantee a corr...

Page 4: ...her information on using the START and STOP inputs please refer to the TEACH IN procedure section I out current analog output I out provides the current analog signal AI1 output range is min quote 4 m...

Page 5: ...of the travel the encoder will provide the minimum current voltage signal level of the output range 4 mA for AI1 0 V for AV2 After the last position of the travel the encoder will provide the maximum...

Page 6: ...r AV2 For a descending ramp as shown in the figure on the previous page activate the START input and then move backward the axis in reverse of the standard direction before activating the STOP input i...

Page 7: ...d incorrectly the active part of the tape does not match the active side of the sensor A magnetic part or a protection surface is interposed between the sensor and the tape Only non magnetic materials...

Page 8: ...1 s OFF Several errors are active in the same time Note When you execute theTEACH IN as soon as you activate the START input the LED switches off As soon as you activate the STOP input it switches on...

Reviews: