Flow Control –
Accommodates
a variety of methods of busy terminal signaling, Including: None, Hardware, Software, Alt-
Hardware and Alt-Software. See Previous Page
4
for more Details.
Default is Hardware.
Increment Cap Codes by 8 –
If
“Increment Cap Codes by 8”
mode is enabled, for each successive pager ID defined in
the Pager Families section of the encoder database, the associated cap code will be incremented by 8. This mode is
sometimes required in some legacy systems where pager cap codes can only be in increments of 8, e.g. Scope paging
systems.
Default is NOT Enabled.
Restore Defaults Buttons –
Clicking on the Button is any Screen where it available will “Reset” the Screen/Settings to
the Factory Default Configuration.
Station ID –
The WaveWare SPS-5 v9 Series Paging System Supports Morse Code Station ID. If a non-blank station ID
(up to 20 characters) is programmed into the system, it will output the station ID in Morse Code at 20WPM (48 mSec/dot)
at 1200 HZ, every approximately 14 minutes.
If using one of WaveWare’s Paging Frequencies this will Enabled
.