SC5800 User Manual
92
Object ID
Group
Object Type
Access
Description
undeclared, unused messages).
1.3.6.1.4.1.1316.1.1.1.3.1.3 mdrmteOutdoorUnitResetType
INTEGER read-only
This message is read from the
Outdoor Unit and identifies the
last reason for a reset within the
OU.
1.3.6.1.4.1.1316.1.1.1.3.1.4 mdrmteOutdoorUnitLockDetect
INTEGER read-only
The transmit RF synthesizer,
receive RF synthesizer and IF
phased locked loop lock detect
signals are monitored and
reported via this MIB element.
1.3.6.1.4.1.1316.1.1.1.3.2 mdrmteSelfTest
1.3.6.1.4.1.1316.1.1.1.3.2.1 mdrmteFlash
INTEGER read-only
Identifies pass/fail status of the
Indoor Unit's application flash.
1.3.6.1.4.1.1316.1.1.1.3.2.2 mdrmteDRAM
INTEGER read-only
Identifies pass/fail status of the
Indoor Unit's Dynamic RAM.
1.3.6.1.4.1.1316.1.1.1.3.2.3
mdrmteSRAM
INTEGER read-only
Identifies pass/fail status of the
Indoor Unit's Static RAM.
1.3.6.1.4.1.1316.1.1.1.3.2.4 mdrmteLineInterface
INTEGER read-only
Identifies pass/fail status of the
Indoor Unit's Line Interface IC.
1.3.6.1.4.1.1316.1.1.1.3.2.5 mdrmteFPGA
INTEGER read-only
Identifies pass/fail status of the
Indoor Unit's FPGA interface
registers to the microprocessor.
1.3.6.1.4.1.1316.1.1.1.3.2.6 mdrmteFEC
INTEGER read-only
Identifies pass/fail status of the
Indoor Unit's FEC IC electrical
interface.
1.3.6.1.4.1.1316.1.1.1.3.2.7 mdrmteRealTimeClock
INTEGER read-only
Identifies pass/fail status of the
Indoor Unit's Real Time Clock.
1.3.6.1.4.1.1316.1.1.1.3.2.8 mdrmteIndoorUnitResetType
INTEGER read-only
This message is read from the
Indoor Unit and identifies the
last reason for a reset wi thin the
IU.
1.3.6.1.4.1.1316.1.1.1.3.2.9
mdrmteLoopbackMode
INTEGER read-write
Entry defines the loopback
mode of a radio station in terms
of loopback at either the
payload line interface level,
baseband processor level in an
OU or RF loopback in the OU.
1.3.6.1.4.1.1316.1.1.1.3.2.10
mdrmteLoopbackTimeOut
INTEGER read-write
This is the number of seconds
the loopback will run for until it
times out.
1.3.6.1.4.1.1316.1.1.1.3.3
mdrmteTrapManagement
1.3.6.1.4.1.1316.1.1.1.3.3.1
mdrmteTrapFilter
INTEGER read-write
Alarms within the MDR product
are classified as critical, major,
minor or informational. The trap
filter allows screening of alarms
before they are dispatched as
traps.
1.3.6.1.4.1.1316.1.1.1.3.3.2
mdrmteNumberTrapManagers INTEGER
read-only This entry shows the number of
trap managers allowed.
1.3.6.1.4.1.1316.1.1.1.3.3.3
mdrmteTrapManagerTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.3.3.3.1
mdrmteTrapManagerEntry SYNTAX
1.3.6.1.4.1.1316.1.1.1.3.3.3.1.
1
mdrmteTrapManagerIndex INTEGER
1.3.6.1.4.1.1316.1.1.1.3.3.3.1.
2
mdrmteTrapManagerIP IpAddress
read-write
This is the IP address of the
management station that is set
up to detect and act upon
Summary of Contents for SC5800
Page 2: ......
Page 9: ...SPEEDCOM SC5800 User Manual 7...
Page 40: ...SPEEDCOM SC5800 User Manual 38...
Page 60: ...SPEEDCOM SC5800 User Manual 58...
Page 73: ...SPEEDCOM SC5800 User Manual 71...
Page 76: ...SPEEDCOM SC5800 User Manual 74...
Page 77: ...SPEEDCOM SC5800 User Manual 75...
Page 78: ...SPEEDCOM SC5800 User Manual 76...
Page 82: ...SPEEDCOM SC5800 User Manual 80...
Page 102: ......
Page 106: ...SC5800 User Manual 104...