SC5800 User Manual
89
Object ID
Group
Object Type
Access
Description
defines the receive frequency
of the Outdoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.2.13 mdrmteNonAutoBandPlan
INTEGER read-write
Same as mdrMTEBandPlan
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the
Outdoor Unit frequencies
without the “auto recovery”
feature attempting to intervene
and re-establish setup of an
operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.14
mdrmteNonAutoTxFreqPlanD
INTEGER read-write
Same as mdrTxFrequencyPlanD
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the
Outdoor Unit Plan D frequencies
without the “auto recovery”
feature attempting to intervene
and re-establish setup of an
operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.15 mdrmteNonAutoRxFreqPlanD
INTEGER read-write
Same as mdrTxFrequencyPlanD
setting in this MIB group except
“auto recovery” is not enabled -
this allows control of the
Outdoor Unit Plan D frequencies
without the “auto recovery”
feature attempting to intervene
and re-establish setup of an
operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.16
mdrmteNonAutoTxPower
INTEGER read-write
Same as mdrTxPower setting in
this MIB group except “auto
recovery” is not enabled - this
allows control of the Outdoor
Unit power level setting without
the “auto recovery” feature
attempting to intervene and re-
establish setup of an operational
RF Link.
1.3.6.1.4.1.1316.1.1.1.2.3 mdrmteServiceChannel
1.3.6.1.4.1.1316.1.1.1.2.3.1 mdrmteScDataRate
†
3
INTEGER
read-write
Bit rate used across the
wayside service channel link.
1.3.6.1.4.1.1316.1.1.1.2.3.2 mdrmteScDataBits
†
4
INTEGER
read-write The
data width - can be 7 or 8
bits.
1.3.6.1.4.1.1316.1.1.1.2.3.3
MdrmteScParity
INTEGER read-write
Serial channel - set to none, odd
or even.
1.3.6.1.4.1.1316.1.1.1.2.3.4
MdrmteScStopBits
INTEGER read-write
The number of stop bits can be
set to 1 or 2.
1.3.6.1.4.1.1316.1.1.1.2.3.5 mdrmteScFlowControl
INTEGER read-write
Either hardware or no f low
control is used.
1.3.6.1.4.1.1316.1.1.1.2.3.6 mdrmteScStatusDump
INTEGER read-write
Allows the wayside service
(serial) channel to be used as a
diagnostics port [deprecated].
1.3.6.1.4.1.1316.1.1.1.2.4 MdrmteGeneral
1.3.6.1.4.1.1316.1.1.1.2.4.1 MdrmteStationName
DisplayString
read-write
The station name is stored in
the Indoor Unit in non-volatile
3
Fixed at 115.2kbps in Version 1.00 and 2.00, 2.01, 2.02 IU firmware releases.
4
Serial setting – 8 bits, no parity, 1 stop bit
Summary of Contents for SC5800
Page 2: ......
Page 9: ...SPEEDCOM SC5800 User Manual 7...
Page 40: ...SPEEDCOM SC5800 User Manual 38...
Page 60: ...SPEEDCOM SC5800 User Manual 58...
Page 73: ...SPEEDCOM SC5800 User Manual 71...
Page 76: ...SPEEDCOM SC5800 User Manual 74...
Page 77: ...SPEEDCOM SC5800 User Manual 75...
Page 78: ...SPEEDCOM SC5800 User Manual 76...
Page 82: ...SPEEDCOM SC5800 User Manual 80...
Page 102: ......
Page 106: ...SC5800 User Manual 104...