1726 North Ballard Road, Suite 1 - Appleton, WI 54911 - 920.991.9082
Technical Support 855.804.5774 - [email protected]
PTS70057-C
13 MAR 2018
W
E
Serial #
Date Installed
Floors
Travel
Speed
Motor
Voltage
Owner
ALWAYS DE-ENERGIZE ELECTRICAL CIRCUITS
and follow proper tag out procedures during servicing or maintenance of elevator.
SERIES :
114, 116
SEMI-ANNUAL GENERAL
MAINTENANCE CHART
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
USE ONE COLUM N P ER VISIT
ON EVERY VISIT CHECK THE FOLLOWING:
O V E R A LL IN S P E C T IO N
See custo mer and co rrect all co mplaints
Inspect machine space equipment and clean when necessary
Ride car, checking fo r unusual no ise o r o peratio n
Check co nditio n o f car to p, pit equipment, clean when necessary
Check fo r burned o ut lights and replace
P UM P UN IT
M aintain o il tank at pro per level [A W-32]
Check fo r excessive leaks aro und valve and pipe co nnectio ns
Check all electrical co nnectio ns
Test run checking fo r excessive no ise and vibratio n
B leed Jack
J A C K
Check plunger fo r signs o f rust and scratches
Check packing gland fo r leakage
Check pipe rupture valve fo r leakage
Check wear and leakage o f ho se/pipe
Check pit bucket and empty
Clean and lubricate ro llers
C O N T R O LLE R
Check co ntacts fo r excessive burning and clean
Check and test battery device
Check fuses, ho lders, and replace if necessary
G A T E
Check gate o peratio n
Check and clean gate o perato r & switches
C A R
Check alarm bell system
Check emergency sto p switch
Check adjustment o f car guide blo cks
Check ro ller wheels/guides
Check hall butto n co ntacts, clean if required
Check o peratio n and mo vement o f slack cable/bro ken ro pe safety
Check COP lights
Check co ntacts and switches in car o perating panel
Check telepho ne is functio ning
H O IS T WA Y
Check rail bracket fasteners are secure and lubricate rail
Check ro pes fo r equal tensio n
Check and clean main guide rails and guide blo cks
Check wear and insulatio n o n traveling cable
Check junctio n bo x
Check and clean interlo cks
Inspect and lubricate ro pes ( Nyro sten Ro peo il Co mpo und)
Test Emergency Light
Check slack ro pe switch and pit switch
Final Limits and P it Switch
Check Car To p Sto p Switch
Date
Technician
Maintenance Messages
LUBRICATION
RECOMMENDATIONS
:
- Use spray lubricant that
meets and/or exceeds MIL-C-
81309D & MIL-C-16173D.
- Approved elevator rope
lubricant should be applied
sparingly to penetrate but not
drip from the rope.