1726 North Ballard Road, Suite 1 - Appleton, WI 54911 - 920.991.9082
Technical Support 855.804.5774 - [email protected]
W
E
PTM30179-D
09 MAR 2018
Manually verify equal tension between wire
ropes and wire rope is clear of all obstructions.
Manually verify both safeties set simultaneously
before testing safeties with a full load.
3"
1-1/2"
DEAD SIDE
(NON LOAD
BEARING)
WEDGE
LIVE SIDE
(LOAD BEARING)
CABLE
CLAMP
ASSEMBLED
Note: The live side wire rope should be in line with the shackle rod.
6.
7
7.
8.
7, 9
A)
B)
B
A
9.
10.
10
CRUSH
HAZARD
CUTTING
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
CRUSH
HAZARD
FALLING
HAZARD
CRUSH
HAZARD
KINK
HAZARD
CRUSH
HAZARD
PINCH
HAZARD
WIRE ROPE
INSTALLATION
SERIES :
114
Pull the slop out of the shackle springs on sling side and clamp in place.
Note:
Verify wire ropes are not crossed at any point throughout their complete length.
Route the wire rope through the shackle socket closet to the rail wall while pulling down on the wire rope
to seat the shackle tightly in the pedestal base. Loop the wire rope up back through the shackle socket
while continuing to hold the tension on the wire rope. Insert the wedge into the newly formed loop and
pull on the dead end of the wire rope to seat the wedge into the shackle socket. Repeat this step for the
other shackle.
Verify the tension is equal on each wire rope and
adjust as needed.
Fasten (4) cable clamps into the designated
locations as described below:
The
fi rst clamp shall be placed a maximum
of 4 times the rope diameter above the
shackle.
(Example: 3/8” wire rope = maximum
distance of 1-1/2”)
The second clamp shall be located within
8 times the rope diameter above the fi rst
clamp
(Example: 3/8” wire rope = maximum
distance of 3”)
Install the anti-rotation brackets into
the shackles and secure.
Page 30