1726 North Ballard Road, Suite 1 - Appleton, WI 54911 - 920.991.9082
Technical Support 855.804.5774 - [email protected]
PTE10194-D
13 MAR 2018
W
E
ELECTRIC
HAZARD
ANTI-
STATIC
ALERT
AUTO GATE PROGRAM
SERIES :
008, 021, 022, 114, 115, 116, 118, 210
Auto Gate Program
Press the Corresponding
Call Floor Button.
Move Elevator to Desired Floor.
NOTE: Elevator must be on EZ
magnet/input.
Flip SW1 to "CLOSED" POSITION.
(located inside controller)
Press the
Corresponding
Call Floor Button.
(with all doors &
gates closed)
AG1 AG2 AG3
Gray square
indicates AG
programmed to
open.
PRESS 7x
’s
NOTE:
Unit will not accept floor calls with SW1 in
closed position.
Reference chart for
number of times to
push the button.
Flip SW1 to
"OPEN" POSITION
TO END this floor's
programming.
NOTE:
Unit will not accept floor
calls with SW1 in
closed position.
Move Elevator
to Any Other Desired
Floor and Repeat.
PRESS 1x’s
PRESS 3x’s
PRESS 2x’s
PRESS 4x’s
PRESS 5x’s
PRESS 6x’s
PRESS 0x’s
Wrong Gates
Opens.
All Desired Gates
Open Correctly.
WINDING DRUM CONTROLLER SHOWN
SW1 Switch shown
in closed position
CLOSED
SWITCH POSITION
CLOSED
SWITCH POSITION
OPEN
SW1
SWI
HYDRAULIC CONTROLLER SHOWN
SW1 Switch shown
in closed position
OPEN
Closed
Page 64