background image

4

709 

3

/

4

" – 2"

 

EDP No. 

Kit No. 

Size

First or Second Check Kits 

in. 

mm

 

0887150 

RK 709 CK4 

3

4

 – 1 

20-25

 

0887151 

RK 709 CK4 

1

1

2

 – 2 

32-50

 

0887154 

RK 709 CK4SS* 

3

4

 – 1 

20-25

 

0887155 

RK 709 CK4SS* 

1

1

2

 – 2 

32-50

Kit includes: Disc assembly, Spring, Seat, Seat o-ring and Cover O-ring.

Complete Rubber Parts

 

0887152 

RK 709 RT 

3

4

 – 1 

20-25

 

0887153 

RK 709 RT 

1

1

2

 – 2 

32-50

Kit includes: Diaphragm, Disc assembly, Seat o-ring and Cover o-ring.

Seat Kits

 

0887160 

RK 709 S4 

3

4

 – 1 

20-25

 

0887161 

RK 709 S4 

1

1

2

 – 2 

32-50

 

0887162 

RK 709 S4SS* 

3

4

 – 1 

20-25

 

0887163 

RK 709 S4SS* 

1

1

2

 – 2 

32-50

Cover Kits

 

0887156 

RK 709 C1 

3

4

 – 1 

20-25

 

0887157 

RK 709 C1 

1

1

2

 – 2 

32-50

 

0887158 

RK 709 C2 

3

4

 – 1 

20-25

 

0887159 

RK 709 C2 

1

1

2

 – 2 

32-50

Kit includes: Cover and Cover o-ring.

*Stainless Steel

1. 

After removing the cover screw, the check comes out  

 

with the cover.

2. 

Holding the check Valve module in both hands, rotate 

 the 

assembly 

1

4

 turn. This will disengage the disc and 

 

spring assembly into individual components. The disc 

 

assembly may be cleaned or replaced. O-rings should 

 

be cleaned or replaced as necessary and lightly greased 

  with the FDA approved silicon grease. Reassemble 
 

the check valve module in the reverse order. 

 

NOTE: 

The springs of the fi rst and second check valves 

 are 

interchangeable.

 

(Before servicing, be certain water is turned off or 

 

shutoff valves are closed)

First Check

Second Check

Cover

Cover
O-ring

Spring

Disc
Holder
Assembly

Seat

Seat
O-ring

Rubber Parts

Kit

First Check
Kit

Second Check
Kit

Rubber 

Parts

Kit

Service, Replacement Parts and Maintenance 

3

/

4

" – 2" (20-50mm)

RP-IS-709_709DCDA.indd   4

9/26/08   2:28:14 PM

Summary of Contents for Series 709

Page 1: ... sentative on back page IMPORTANT Inquire with governing authorities for local installation requirements NOTE For Australia and New Zealand line strainers should be installed between the upstream shutoff valve and the inlet of the backflow preventer Its important that this device be tested periodically in compliance with local codes but at least once per year or more as service conditions warrant ...

Page 2: ... it is important that the valve be easily accessible to facilitate testing and servicing Outdoor Installations In area where freezing conditions do not occur Series709canbeinstalledoutsideof abuilding Themostsatisfactoryinstallation is above ground and should be installed in this manner whenever possible Itisgenerallyrecommendedthatbackflow preventers never be placed in pits unless absolutely nece...

Page 3: ... Test 6 Close shutoff valve No 2 then No 1 7 Slowly open VA and lower high side pressure about 2 psid below the low side pressure differential read ing about 2 0 psid Close VA If reading is maintained record as tight If reading returns to 0 and the pressure A increases to pressure B the check is recorded as leaking If the reading returns to psid No 2 shutoff valve is leaking excessively and must b...

Page 4: ... RK 709 C2 11 2 2 32 50 Kit includes Cover and Cover o ring Stainless Steel 1 After removing the cover screw the check comes out with the cover 2 Holding the check Valve module in both hands rotate the assembly 1 4 turn This will disengage the disc and spring assembly into individual components The disc assembly may be cleaned or replaced O rings should becleanedorreplacedasnecessaryandlightlygrea...

Page 5: ...er O ring Complete Rubber Parts 0887915 RK 709 RT 21 2 3 65 80 0887916 RK 709 RT 4 100 0887917 RK 709 RT 6 150 0887918 RK 709 RT 8 200 0887919 RK 709 RT 10 250 Kit includes Two discs and Two Cover O rings Seat Kits 0887910 RK 709S 21 2 3 65 80 0887911 RK 709S 4 100 0887912 RK 709S 6 150 0887913 RK 709S 8 200 0887914 RK 709S 10 250 Kit includes Seat Seat o ring Retainer Wire and Cover O ring Cover ...

Page 6: ...s vent Installed At All cross connections subject to backpressure or back siphonage where there is a high potential health contamination Continuous pressure Fire protection system supply main Detects leaks and unauthorized use of water All cross connections subject to backpressure or back siphonage where there is a low potential health contamination Continuous pressure Fire protection system suppl...

Page 7: ...emble clean or replace check open e Weak or broken spring Disassemble and replace spring 2 Chatter during flow a Worn damaged or Disassemble and repair or conditions defective guide replace guide 3 Low flows passing a Mainline check fouled Disassemble and clean through mainline valve 709DCDA only b Meter strainer plugged Disassemble and clean c Damaged mainline seat Disassemble and replace disc or s...

Page 8: ...r breach of warranty and the Company shall not be responsible for any incidental special or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water condi...

Reviews: