background image

12                                                                         PWF Filter Systems

Programming

STEP 1SS –

 

From normal mode, press SET HOUR + UP buttons simultaneously for 3 seconds and 

release. Then press SET HOUR + UP buttons simultaneously for 3 seconds and release.

STEP 2SS –

 

Choose the desired program by pressing the UP or DOWN buttons. Prior to selecting a 

program, verify the correct valve body, main piston, regenerant piston, and stack are being used, and that 

the injector or injector plug(s) are in the correct locations. See Compliance Table in Service Instructions 

under Injector Cap, Screen, Injector Plug and Injector section and Figure 6. Press SET HOUR button to 

go to Step 3SS.

Program

Cycle Sequence, Adjustable Default Times (minutes)

C1 

1st Backwash

C2 

Regenerate

C3 

2nd Backwash

C4 

Rinse

C5 
Fill

P0

3

50

3

3

1-99

P1

8

50

8

4

1-99

P2

8

70

10

6

1-99

P3

12

70

12

8

1-99

P4

10

50

Skipped

8

1-99

P5

4

50

Skipped

4

1-99

P6

12

6

Skipped

12

1-99

P7

6

Skipped

Skipped

4

P8

10

Skipped

Skipped

6

The control valve offers multiple procedures that allow the valve to be modifi ed to suit the needs of the 

installation. These procedures are:
  • OEM System Setup
  • Installer Displays & Settings (either 1-99 Days Between Regeneration option or 7-Day option)
  • User Displays
These procedures can be accessed in any order. Details on each of the procedures are provided below and 

on the following pages.
When in operation, normal user displays show the time of day or days remaining before backwash. When 

stepping through a procedure, if no buttons are pressed within five minutes the display returns to a normal 

user display. Any changes made prior to the five minute time out are incorporated.
To quickly exit Installer Displays & Settings or OEM Setup, simultaneously press SET HOUR + DOWN. Any 

changes made prior to the exit are incorporated.
To reinitialize the control valve, check to make sure the valve is in the User Display. Then simultaneously 

press SET HOUR + DOWN or unplug power source plug (black wire) on the circuit board, and plug back in.

OEM System Setup

Regeneration Cycles and Times for Different Programs

STEP 3SS –

 

If program P0 through P6 was selected, enter in the minutes of fill using the UP or DOWN 

buttons. The allowable values vary from a low of 1 to a high of 99. If program P7, P8 or P9 was selected, 

dashes will appear for minutes of fill. Press SET HOUR button to go to Step 4SS. Note: For each minute 

of fill 0.5 gallons of water

STEP 1SS

STEP 2SS

SET 

HOUR

SET 

HOUR

SET 

HOUR

Regen 

Min. Fill 

Regen

Hour

Time-Hour 

PM 

Days To Regen

STEP 3SS

Regen 

Min. Fill 

Regen

Hour

Time-Hour 

PM 

Days To Regen

SET 

HOUR

Summary of Contents for PWFCAL15

Page 1: ...governing authorities for additional local requirements WARNING Need for Periodic Inspection Maintenance This product must be tested periodically in compliance with local codes but at least once per...

Page 2: ...6 15 5 3 16 X 11 X 62 PWFGAC2 Time Clock 12 X 52 2 30 8 15 7 5 17 X 13 X 60 PWFGAC3 Time Clock 14 X 65 3 40 11 15 10 18 X 14 X 74 PWFGAC4 Time Clock 16 X 65 4 60 14 15 11 20 X 17 X 74 MODEL NO VALVE...

Page 3: ...outlet must be grounded All electrical connections must be connected according to local codes Be certain the outlet is uninterrupted Install grounding strap on metal pipes The power adapter comes with...

Page 4: ...ipment If there is obvious damage to any equipment it should be noted on the carrier s Bill Of Lading Open and inspect the contents of all closed crates cartons etc and inspect for concealed damage Th...

Page 5: ...e oils or hydrocarbon based lubricants Use only 100 silicone lubricants Do not support the weight of the system on the control valve fittings plumbing or the bypass Do not allow this water conditionin...

Page 6: ...bracket towards the two latches The Service Instructions Figure 17 Figure 18 Figure 19 Figure 20 NOTICE NOTICE NOTICE Install a By Pass Always install a bypass either a 3 way valve system or the stan...

Page 7: ...es for an electrical ground metal only When finished with plumbing a ground wire should be connected to the copper pipes to complete the ground circuit Use two clamps and 4 copper for this Figure 5 Wh...

Page 8: ...ct to the control valve or the bypass valve using nuts that only require hand tighten ing Hand tighten nut connections between control valve and installation fittings control valve and bypass valve an...

Page 9: ...om the drain line When water is clear press the regen button 4 times This will take the valve back to service position Open several cold water and hot water faucets and let run until hot water heater...

Page 10: ...he Quick Programming Guide please see the detailed programming section of this manual NOTICE The electronics in the PWF control valve are used across a wide variety of control valves and applications...

Page 11: ...the hour the regeneration should occur by using the Up and Down arrow buttons an arrow points to PM after 12 00 noon Late night midnight is best this is the time when no water is liekly to be used Pr...

Page 12: ...7 Day option User Displays These procedures can be accessed in any order Details on each of the procedures are provided below and on the following pages When in operation normal user displays show th...

Page 13: ...points at Regen Hour Use UP or DOWN buttons to switch between the two choices If a differential switch is not installed the settings in this display are ignored NOTE A backwash will be initiated or s...

Page 14: ...rent day of the week by using the UP or DOWN buttons See chart at right for date codes Press SET HOUR to go to STEP 4I7 STEP 4I7 Sunday backwash To backwash on Sunday use the UP or DOWN button until t...

Page 15: ...ill always read 7 and a regeneration will never occur User Displays General Operation When the system is operating one of two displays will be shown Pressing UP or DOWN button will alter nate between...

Page 16: ...ests or a heavy laundry day To initiate a manual backwash at the preset delayed backwash time simultaneously press UP DOWN buttons together and release The arrow will point to the word Regen if a rege...

Page 17: ...PWF Filter Systems 17 NOTES...

Page 18: ......

Page 19: ......

Page 20: ...IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT SHALL WATTS BE LIABLE IN CONTRACT TORT STRICT LIABILITY OR UNDER ANY...

Reviews: