is added to the solution tank. With salt (sodium chloride) this
equates to approximately 1 1/2 pounds of salt per minute of fill.
STEP 4SS
— Use UP or DOWN buttons to switch between:
• 1-99 Days Between Regen; or
• 7-Day.
Press SET HOUR button to go to Step 5SS.
STEP 5SS
— Use UP or DOWN buttons to switch between 60 Hz
or 50 Hz option. Press SET HOUR button to go to Step 6SS.
STEP 6SS
— If a differential pressure switch is installed and actu-
ated:
• a backwash will occur immediately if no arrow points at Regen
Hour; or
• a backwash will occur at the delayed regeneration hour if an
arrow points at Regen Hour.
Use UP or DOWN buttons to switch between the two choices. If
a differential switch is not installed the settings in this display are
ignored.
NOTE: A backwash will be initiated or scheduled after the control has
received a signal for two minutes.
A. Differential pressure switch connection
B. Motor wire connection
C. AC adapter wire connection
STEP 5SS
STEP 6SS
STEP 4SS
or
Return to
Normal Mode