PWFGAC PWFMZ PWFC Series

 IOM-WQ-PWFGAC-PWFMZ-PWFCAL

Do not use with water that is microbiologically unsafe or of un-

known quality adequate disinfection before and after the system.

WARNING

!

NOTICE

H

ydrocarbons such as Kerosene, Benzene, Gasoline, 

etc., may damage products that contain O-rings or plastic 

components. Exposure to such hydrocarbons may cause the 

products to leak. Do not use the product(s) contained in this 

document on water supplies that contain Hydrocarbons such 

as Kerosene, Benzene, Gasoline, etc

.

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information can 

result in death, serious personal injury, property damage, or 

damage to the equipment.
Keep this Manual for future reference.

You are required to consult the local building and plumbing 

codes prior to installation.  If the information in this manual 

is not consistent with local building or plumbing codes, 

the local codes should be followed. Inquire with governing 

authorities for additional local requirements.

WARNING

!

Need for Periodic Inspection/Maintenance:

  This product must 

be tested periodically in compliance with local codes, but at least 

once per year or more as service conditions warrant.  All prod-

ucts must be retested once maintenance has been performed.  

Corrosive water conditions, and/or unauthorized adjustments or 

repair could render the product ineffective for the service intended.  

Regular checking and cleaning of the product’s internal compo-

nents helps assure maximum life and proper product function. 

WARNING

!

Series PWFGAC, PWFMZ, PWFCAL
Installation, Operation  
and Maintenance Manual

System Specification Table  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General Warnings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
How to Use this Manual   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Control Valve Function and Cycles of Operation . . . . . . . . . . . . . . . . . . . . 4
Installation Preview   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pre-Installation Considerations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

 

General Installation Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Bypass Valve Installation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Move Filter System Into Place  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Connect the Drain Line  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Start Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PWF System Programming  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PWF Quick Programming Guide  . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PWF OEM System Setup Programming. . . . . . . . . . . . . . . . . . . 12-13
PWF Installer Display and Settings. . . . . . . . . . . . . . . . . . . . . . . 14-15
PWF User Displays  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16
NOTES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Table of Contents

Summary of Contents for PWFCAL15

Page 1: ...governing authorities for additional local requirements WARNING Need for Periodic Inspection Maintenance This product must be tested periodically in compliance with local codes but at least once per...

Page 2: ...6 15 5 3 16 X 11 X 62 PWFGAC2 Time Clock 12 X 52 2 30 8 15 7 5 17 X 13 X 60 PWFGAC3 Time Clock 14 X 65 3 40 11 15 10 18 X 14 X 74 PWFGAC4 Time Clock 16 X 65 4 60 14 15 11 20 X 17 X 74 MODEL NO VALVE...

Page 3: ...outlet must be grounded All electrical connections must be connected according to local codes Be certain the outlet is uninterrupted Install grounding strap on metal pipes The power adapter comes with...

Page 4: ...ipment If there is obvious damage to any equipment it should be noted on the carrier s Bill Of Lading Open and inspect the contents of all closed crates cartons etc and inspect for concealed damage Th...

Page 5: ...e oils or hydrocarbon based lubricants Use only 100 silicone lubricants Do not support the weight of the system on the control valve fittings plumbing or the bypass Do not allow this water conditionin...

Page 6: ...bracket towards the two latches The Service Instructions Figure 17 Figure 18 Figure 19 Figure 20 NOTICE NOTICE NOTICE Install a By Pass Always install a bypass either a 3 way valve system or the stan...

Page 7: ...es for an electrical ground metal only When finished with plumbing a ground wire should be connected to the copper pipes to complete the ground circuit Use two clamps and 4 copper for this Figure 5 Wh...

Page 8: ...ct to the control valve or the bypass valve using nuts that only require hand tighten ing Hand tighten nut connections between control valve and installation fittings control valve and bypass valve an...

Page 9: ...om the drain line When water is clear press the regen button 4 times This will take the valve back to service position Open several cold water and hot water faucets and let run until hot water heater...

Page 10: ...he Quick Programming Guide please see the detailed programming section of this manual NOTICE The electronics in the PWF control valve are used across a wide variety of control valves and applications...

Page 11: ...the hour the regeneration should occur by using the Up and Down arrow buttons an arrow points to PM after 12 00 noon Late night midnight is best this is the time when no water is liekly to be used Pr...

Page 12: ...7 Day option User Displays These procedures can be accessed in any order Details on each of the procedures are provided below and on the following pages When in operation normal user displays show th...

Page 13: ...points at Regen Hour Use UP or DOWN buttons to switch between the two choices If a differential switch is not installed the settings in this display are ignored NOTE A backwash will be initiated or s...

Page 14: ...rent day of the week by using the UP or DOWN buttons See chart at right for date codes Press SET HOUR to go to STEP 4I7 STEP 4I7 Sunday backwash To backwash on Sunday use the UP or DOWN button until t...

Page 15: ...ill always read 7 and a regeneration will never occur User Displays General Operation When the system is operating one of two displays will be shown Pressing UP or DOWN button will alter nate between...

Page 16: ...ests or a heavy laundry day To initiate a manual backwash at the preset delayed backwash time simultaneously press UP DOWN buttons together and release The arrow will point to the word Regen if a rege...

Page 17: ...PWF Filter Systems 17 NOTES...

Page 18: ......

Page 19: ......

Page 20: ...IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT SHALL WATTS BE LIABLE IN CONTRACT TORT STRICT LIABILITY OR UNDER ANY...

Reviews: