background image

5

 Parts List

IteM #

OrderIng cOde

descrIPtIOn

1

7300767

3/8" Brass Insert (not shown)

2

7300768

3/8" Delrin Sleeve (not shown)

3

7300769

3/8" Brass Nut

4

7300067

3/8" Blue Tubing

5

7300770

3/8" QC Union

6

7300771

3/8" QC Stem Adapter

7

7300766

System Head Assembly

8

7100643

15" HC Carbon Filter

Under Counter System

5

3

6

4

7

8

2
1

To Loosen      To Tighten

WATTS 

8716 W Ludlow Drive Suite #1
Peoria, AZ 85381

PWDWHCUC1

GENERAL USE CONDITIONS:

1: System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality .  DO NOT 

use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system . Systems certified 

for cyst reduction may be used on disinfected waters that may contain filterable cysts .

2: Operating Temperature:    

Maximum 100

F (38

C) 

Minimum 40

F (4 .4

C)

3: Operating Water Pressure: 

Minimum 25-psi (172kpa)

4: Maximum flow Rate: 

5: Rated Capacity (Chlorine):  

Maximum 

  

1

25

-psi (689kpa) 

1 .6 gpm      (6 .06 lpm)

 

10000 Gallons (37,854 liters)

RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:

Depending on incoming feed water conditions  

replacement time frame may vary .

Description 

Part Number 

Change time Frame

PWCBHCUC1 

7100643 

10000 gallons of water

Performance Data Sheet

The PWDWHCUC1 is certified to NSF/ANSI 42 for 

reduction of aesthetic chlorine, taste and odor, 

NSF/ANSI 53 for the reduction of cysts, and NSF/

ANSI 372 for lead free compliance.

WARNING

!

The PWDWHCUC1 system has been tested according to NSF/ANSI 42, 53, for reduction of the substances listed below. The concentration of 

the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water 

leaving the system, as specified in NSF/ANSI 42.

While testing was performed under standard laboratory conditions, actual performance may vary.

Testing parameters: 

Flow rate 1.6 gpm 

pH 7.6 gpm 

Water pressure: 60 psi.

Cyst Reduction 

Flow Reduction 

Influent 

Effluent 1 

Effluent 2

Influent 

Avg.

370000 

count/L

Eighth 

Cycle

130000

<25

<25

Effluent 

Avg.

<25 

count/L

25%

210000

<25

<25

Percent 

Reduction

>99.98 

%

50%

333000

<25

<25

Maximum 

Effluent

<25 

 

count/L

75%

810000

<25

<25