5
Parts List
IteM #
OrderIng cOde
descrIPtIOn
1
7300767
3/8" Brass Insert (not shown)
2
7300768
3/8" Delrin Sleeve (not shown)
3
7300769
3/8" Brass Nut
4
7300067
3/8" Blue Tubing
5
7300770
3/8" QC Union
6
7300771
3/8" QC Stem Adapter
7
7300766
System Head Assembly
8
7100643
15" HC Carbon Filter
Under Counter System
5
3
6
4
7
8
2
1
To Loosen To Tighten
WATTS
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
PWDWHCUC1
GENERAL USE CONDITIONS:
1: System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality . DO NOT
use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system . Systems certified
for cyst reduction may be used on disinfected waters that may contain filterable cysts .
2: Operating Temperature:
Maximum 100
o
F (38
o
C)
Minimum 40
o
F (4 .4
o
C)
3: Operating Water Pressure:
Minimum 25-psi (172kpa)
4: Maximum flow Rate:
5: Rated Capacity (Chlorine):
Maximum
1
25
-psi (689kpa)
1 .6 gpm (6 .06 lpm)
10000 Gallons (37,854 liters)
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Depending on incoming feed water conditions
replacement time frame may vary .
Description
Part Number
Change time Frame
PWCBHCUC1
7100643
10000 gallons of water
Performance Data Sheet
The PWDWHCUC1 is certified to NSF/ANSI 42 for
reduction of aesthetic chlorine, taste and odor,
NSF/ANSI 53 for the reduction of cysts, and NSF/
ANSI 372 for lead free compliance.
WARNING
!
The PWDWHCUC1 system has been tested according to NSF/ANSI 42, 53, for reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42.
While testing was performed under standard laboratory conditions, actual performance may vary.
Testing parameters:
Flow rate 1.6 gpm
pH 7.6 gpm
Water pressure: 60 psi.
Cyst Reduction
Flow Reduction
Influent
Effluent 1
Effluent 2
Influent
Avg.
370000
count/L
Eighth
Cycle
130000
<25
<25
Effluent
Avg.
<25
count/L
25%
210000
<25
<25
Percent
Reduction
>99.98
%
50%
333000
<25
<25
Maximum
Effluent
<25
count/L
75%
810000
<25
<25