 Performance Data Sheet

Model: RO-PURE

General Use Conditions

1.   System to be used with municipal or well water sources treated 

and tested on regular basis to insure bacteriological safe quality. 

Systems certified for cyst reduction may be used on disinfected 

water that may contain filterable cysts.

 

WARNING

!

DO NOT use with water that is micro biologically unsafe or 

unknown quality without adequate disinfection before and 

after the system. 

2.  This system is acceptable for treatment of influent concentrations 

of no more than 65 mg/L nitrate and 5 mg/L nitrite in combina-

tion measured as N and is certified for nitrate/nitrite reduction only 

for water supplies with a pressure of 350 kPa (50 psig) or greater 

along with an internal built in booster pump.

3.  Operating Temperature:    Maximum: 100°F (40.5°C)  

Minimum: 40° (4.4°)

4.  Operating Water Pressure:  Maximum: 85 psi (6.0kg/cm2)  

Minimum: 40 psi (2.8kg/cm2)

5. pH  

 Maximum: 11  

Minimum: 2

6.  Maximum Iron present in incoming water supply must be less  

than 0.2 ppm.

7.  Hardness of more than 10 grains per gallon (170 ppm) may  

reduce RO membrane life expectancy.

8.  Recommend TDS (Total Dissolved Solids) not to exceed  

1800 ppm.

DESCRIPTION

PART# 

CHANGE TIME FRAME

Sediment Pre-Filter

WP105311

6 Months

Carbon Pre-Filter

WP105351

6 Months

Final Carbon Filter

WP105341

12 Months

50 GPD RO Membrane

WP105331

2 to 5 Years

Recommended Replacement Parts and 

Change Intervals

Note:  

Depending on incoming feed water conditions, replacement 

time may vary. 

While testing was performed under standard laboratory condi-

tions, actual performance may vary depending on water chemistry, 

water temperature, and water pressure. Efficiency rating means the 

percentage of the influent water to the system that is available to the 

user as reverse osmosis treated water under operating conditions 

that approximate typical daily usage. Recovery rating means the per-

centage of the influent water to the membrane portion of the system 

that is available to the user as reverse osmosis treated water when 

the system is operated without a storage tank or when the storage 

tank is bypassed. There is an average of 4 gallons of reject water for 

every 1 gallon of product water produced.

REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR 

FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY 

INFORMATION. 

Watts Premier  •  8716 W Ludlow Drive, Suite 1  • Peoria, AZ 85381  •  Phone: 800-752-5582

IOM-Premier-RO-PURE.indd   11

7/10/20   2:32 PM

Summary of Contents for Premier RO-PURE

Page 1: ...to a surface strong enough to support its weight System tested and certified by WQA against NSF ANSI Standard 58 for the reduction of the claims specified on the performance data sheet and to NSF ANSI...

Page 2: ...ly reduced Stage 3 Membrane recommended change 2 5 years Stage three is the heart of the reverse osmosis system the 50GPD Gallons Per Day RO membrane This semi permeable membrane will effectively remo...

Page 3: ...134018 1 4 QC x 1 4 FPT Tank Ball Valve 7 WP228173 Fitting 3 8 Stem x 1 4 QC Adapter 8 WP164056 Drain Saddle 3 8 Kit 9 WP610109 4 Green 1 4 Tubing 10 WP610113 4 Blue 1 4 Tubing 11 WP400048 3 Black 3 8...

Page 4: ...itting With the collet held in this position the tube can be removed The fitting can then be reused STEP 1 NOTICE Water supply line to the system must be from the cold water supply line only Hot water...

Page 5: ...faucet may push up out of position Prior to the install hold the faucet as shown in the picture and pull down on the wing nut This will ensure that the O rings are in their proper position and that y...

Page 6: ...ough one side of the drain pipe Step C The drain saddle must be installed at least 1 above the nut of the P Trap elbow or cross bar from the garbage disposal to insure proper drainage Using the 3 8 dr...

Page 7: ...en so it can easily be closed to prevent water flowing to the ice maker during start up and periodic maintenance An Ice maker Connection Kit can be purchased through Premier Startup NOTICE If your RO...

Page 8: ...conditions and the amount the RO system is used This reverse osmosis membrane is critical for effective reduction of total dissolved solids TDS The product water should be tested periodically to verif...

Page 9: ...es then continue rinsing eye Call a poison control center or doctor for treatment advice Check Air Pressure in the Tank Procedure for Extended Non Use More than 2 months NOTICE Check air pressure only...

Page 10: ...water Set tank air pressure between 5 7psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7psi See Page 9 4 Noise Water from faucet...

Page 11: ...S Total Dissolved Solids not to exceed 1800 ppm DESCRIPTION PART CHANGE TIME FRAME Sediment Pre Filter WP105311 6 Months Carbon Pre Filter WP105351 6 Months Final Carbon Filter WP105341 12 Months 50 G...

Page 12: ...7 43 50 psi 0 1 11 1 mg L 0 5 NTU Nitrate Nitrite N A N A 83 30 N A N A N A N A N A Recovery 25 5 Daily Production Rate 23 5 GPD Efficiency 12 8 This system has been tested according to NSF ANSI 58 fo...

Page 13: ...senic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is us...

Page 14: ...cord DATE OF PURCHASE MODEL NUMBER SERIAL NUMBER DATE OF INSTALL INSTALLED BY INSTALLED BY DATE SEDIMENT 6 MONTHS PRE CARBON 6 MONTHS POST CARBON 1 YEAR RO MEMBRANE 2 5 YEARS IOM Premier RO PURE indd...

Page 15: ...ions from abuse misuse misapplication improper maintenance neglect alteration accidents casualties fire flood freezing environmental factors water pressure spikes or other such acts of God This warran...

Page 16: ...IOM Premier RO PURE indd 16 7 10 20 2 32 PM...

Reviews: