Performance Data Sheet -Cont'd
Performance Claims
AVERAGE
INFLUENT
(MG/L)
AVERAGE
EFFLUENT
(MG/L)
% REDUCTION
PH
PRESSURE
MAXIMUM
EFFLUENT
(MG/L)
INFLUENT
CHALLENGE
CONCENTRATION
MAXIMUM
ALLOWABLE
CONCENTRATION
(MG/L)
Arsenic
(Pentavalent)
0.31
0.001
99.20%
7.24
50 psi
0.002
0.30 +/- 10%
0.010
Barium
9.2
0.08
97.60%
7.64
50 psi
0.12
10.0 +/- 10%
2.0
Cadmium
0.031
0.0004
98.00%
7.49
50 psi
0.0008
0.03 +/- 10%
0.0005
Chromium
(Hexavalent)
0.3
0.002
98.50%
7.24
50 psi
0.004
0.03 +/- 10%
0.1
Chromium
(Trivalent)
0.3
0.001
96.70%
7.64
50 psi
0.002
0.03 +/- 10%
0.1
Copper
3.2
0.02
98.70%
7.4
50 psi
0.04
3.0 +/- 10%
1.3
Cyst
92,000 / ml
3 / ml
99.97%
7.44
50 psi
18
min. 50,000/ml
N/A
Fluoride
8.7
0.19
95.70%
7.24
50 psi
0.3
8.0 +/- 10%
1.5
Lead
0.15
0.002
96.60%
7.39
50 psi
0.005
0.15 +/- 10%
0.0107
Perchlorate
130
2.8
96.90%
N/A
N/A
N/A
N/A
N/A
Radium 226 / 228
25 pCi/L
5 pCi/L
80%
7.24
50 psi
5 pCi/L
25 pCi/L
5 pCi/L
Selenium
94.85
< 0.2
97%
7.24
50 psi
< 0.2
0.10 +/- 10%
0.05
TDS
770
35
96.40%
7.28
50 psi
26
750 +/- 40 mg/L
187
Turbidity
11.3
0.1
99%
7.43
50 psi
0 - 1
11 +/- 1 mg/L
0.5 NTU
Nitrate / Nitrite
N/A
N/A
83.30%
N/A
N/A
N/A
N/A
N/A
Recovery- 25.5%
Daily Production Rate-23.5 GPD
Efficiency-12.8%
This system has been tested according to
NSF/ANSI 58 for reduction of the substances
listed below, and to NSF/ANSI 372 for lead
free compliance.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system as specified
in NSF/ANSI 58. This system has been tested for the treatment
of water containing pentavalent arsenic (also known as As (V),
As (+5), or arsenate) at concentrations of 0.30 mg/L or less. This
system reduces pentavalent arsenic, but may not remove other
forms of arsenic. This system is to be used on water supplies
containing a detectable free chlorine residual at the system inlet
or on water supplies that have been demonstrated to contain only
pentavalent arsenic. Treatment with chloramine (combined chlorine)
is not sufficient to ensure complete conversion of trivalent arsenic
to pentavalent arsenic, Please see the Arsenic Facts section for
further information.