background image

5

Note: 

Some sinks have predrilled 1¼" or 1½" holes that are suitable for 

installation of your Drinking Water faucet. If so, please Skip to step Step 3.

NOTICE

Drilling a hole in a sink or countertop for faucet installation is 

entirely out of the control of Watts. Watts accepts no responsi-

bility for damage resulting from installing faucet in any surface 

including marble countertop or a porcelain sink.
For Marble countertops, porcelain sinks and other surfaces: 

ALWAYS use a qualifi ed contractor for drilling a hole in a marble 

counter-top, porcelain sink and other surfaces because they 

can crack and chip easily when drilling the hole.

NOTICE

Always use a diamond-tip drill bit and hole saw.

Step A –

  Determine desired location for the faucet on your sink 

and place a piece of masking 

tape over where the hole is to be 

drilled. Mark the center of the hole 

on the tape.

Step B –

  Using a variable speed drill set on 

the slowest speed, drill a 

1

/

8

" pilot 

hole through both porcelain and 

metal casing of sink at the marked 

center of the desired location. Use 

lubricating oil or liquid soap to 

keep the drill bit cool (If drill 

bit gets hot it may cause the 

porcelain to crack or chip).

Step C –

  Using a 1¼" diamond-tip hole 

saw, proceed to drill the large 

hole. Keep drill speed on the 

slowest speed and use lubricating 

oil or liquid soap to keep the hole saw cool during cutting.

Step D –

   After drilling, remove all sharp edges and make sure the 

surroundings of the sink are cooled before mounting 

the faucet.

 Watts Top Mount Faucet Installation 

STEP 3

This RO faucet is equipped with quick connect fi ttings for easy tube 

installation. To connect tubes, simply push them fi rmly into their cor-

responding fi tting on the RO faucet until fully seated. 

NOTE: 

 

 A 1" to 1¼" mounting hole is required for the 

faucet installation

Step 3-1 –

  During shipping/handling the toggle bolt on your new 

faucet may push up out of position. Prior to the install, 

hold the faucet as shown in the picture and pull down on 

the wing nut. This will ensure that the O-rings are in their 

proper position and that your faucet will have a good seal.

NOTICE

The quick-connect ports on the faucet are color coded. Make sure the 

tube being inserted matches the color of the port. 

Step 3-2 –

  In the parts bag, locate one 

3

8

" Stem x ¼  " Quick connect 

fi tting adapter, one ¼  " red tube, one ¼  " blue tube and one 

3

8

" black tube.

STEP 2

 Drill a Hole for the Faucet in a Sink

Step 3-3 –

 Insert the 

3

8

" Stem adapter into the 

3

8

" fi tting located on 

the end of the toggle bolt assembly.

NOTICE

Approximately ¾  " of ALL tubing must go into the fi tting.

Step 3-4 - 

The BLUE tubing has one BENT end and one STRAIGHT 

end. Connect the STRAIGHT end of the ¼  " BLUE tube fi rmly into 

the faucet fi tting. 

Step 3-5 –

 Connect the 

3

8

" BLACK tube into the bottom of the 

faucet. 

Step 3-6 –

 The RED tubing has one BENT end and one STRAIGHT 

end. Connect the STRAIGHT end of the ¼  " RED tube fi rmly into the 

faucet fi tting. 

Step 3-7 –

  From above the sink, 

feed the faucet tubing 

& toggle bolt down 

through the mounting 

hole in the sink. Test fi t 

the faucet placement.

Step 3-8 –

  Peel the white back-

ing paper off the seal 

on the bottom of the 

faucet base and press 

fi rmly over the mounting 

location

Step 3-9 –

  Insert your Phillips head 

screwdriver through the 

spout hole of the RO 

faucet and then turn 

the toggle bolt until the 

faucet is secure. 

NOTICE

 Do not overtighten

Step 3-10 –

  Insert spout into the 

faucet base until 

fully seated.

Step 3-11 –

  Pull the Battery Safety 

Tab out to activate the 

faucet monitor. Make 

sure that the clear 

drawer is fi rmly seated 

in the faucet base. 

The monitor will fl ash 

briefl y once activated.

KEEP AWAY FROM CHILDREN
This product contains a button (coin) cell battery. If swallowed, 

it could cause severe injury or death in just 2 hours. Seek 

immediate medical help. Contact a Poison Control Center. 

RED 

TUBE

BLACK 

TUBE

BLUE TUBE

FAUCET ADAPTER

TOGGLE BOLT

IOM-Premier-RO-PURE.indd   5

7/10/20   2:32 PM

Summary of Contents for Premier RO-PURE

Page 1: ...to a surface strong enough to support its weight System tested and certified by WQA against NSF ANSI Standard 58 for the reduction of the claims specified on the performance data sheet and to NSF ANSI...

Page 2: ...ly reduced Stage 3 Membrane recommended change 2 5 years Stage three is the heart of the reverse osmosis system the 50GPD Gallons Per Day RO membrane This semi permeable membrane will effectively remo...

Page 3: ...134018 1 4 QC x 1 4 FPT Tank Ball Valve 7 WP228173 Fitting 3 8 Stem x 1 4 QC Adapter 8 WP164056 Drain Saddle 3 8 Kit 9 WP610109 4 Green 1 4 Tubing 10 WP610113 4 Blue 1 4 Tubing 11 WP400048 3 Black 3 8...

Page 4: ...itting With the collet held in this position the tube can be removed The fitting can then be reused STEP 1 NOTICE Water supply line to the system must be from the cold water supply line only Hot water...

Page 5: ...faucet may push up out of position Prior to the install hold the faucet as shown in the picture and pull down on the wing nut This will ensure that the O rings are in their proper position and that y...

Page 6: ...ough one side of the drain pipe Step C The drain saddle must be installed at least 1 above the nut of the P Trap elbow or cross bar from the garbage disposal to insure proper drainage Using the 3 8 dr...

Page 7: ...en so it can easily be closed to prevent water flowing to the ice maker during start up and periodic maintenance An Ice maker Connection Kit can be purchased through Premier Startup NOTICE If your RO...

Page 8: ...conditions and the amount the RO system is used This reverse osmosis membrane is critical for effective reduction of total dissolved solids TDS The product water should be tested periodically to verif...

Page 9: ...es then continue rinsing eye Call a poison control center or doctor for treatment advice Check Air Pressure in the Tank Procedure for Extended Non Use More than 2 months NOTICE Check air pressure only...

Page 10: ...water Set tank air pressure between 5 7psi See previous page Low Pressure in Tank Use a Digital Air Gauge for best results The empty tank pressure should be 5 7psi See Page 9 4 Noise Water from faucet...

Page 11: ...S Total Dissolved Solids not to exceed 1800 ppm DESCRIPTION PART CHANGE TIME FRAME Sediment Pre Filter WP105311 6 Months Carbon Pre Filter WP105351 6 Months Final Carbon Filter WP105341 12 Months 50 G...

Page 12: ...7 43 50 psi 0 1 11 1 mg L 0 5 NTU Nitrate Nitrite N A N A 83 30 N A N A N A N A N A Recovery 25 5 Daily Production Rate 23 5 GPD Efficiency 12 8 This system has been tested according to NSF ANSI 58 fo...

Page 13: ...senic may not con vert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is us...

Page 14: ...cord DATE OF PURCHASE MODEL NUMBER SERIAL NUMBER DATE OF INSTALL INSTALLED BY INSTALLED BY DATE SEDIMENT 6 MONTHS PRE CARBON 6 MONTHS POST CARBON 1 YEAR RO MEMBRANE 2 5 YEARS IOM Premier RO PURE indd...

Page 15: ...ions from abuse misuse misapplication improper maintenance neglect alteration accidents casualties fire flood freezing environmental factors water pressure spikes or other such acts of God This warran...

Page 16: ...IOM Premier RO PURE indd 16 7 10 20 2 32 PM...