background image

2

Installation Precautions

•   Do 

NOT

 install system on line pressure above 100psi.

•   Do 

NOT

 install the system backwards with the feed water 

line connected to the outlet.

•   Do 

NOT

 install system in direct sunlight or where system is 

exposed to harsh chemicals or may be subjected to being 

struck by moving equipment, carts, mops or any other item 

that may cause damage.

•   Do 

NOT

 install the unit behind equipment where it may be  

difficult to access the system for filter replacement. 

• Do 

NOT

 install the OneFlow® system near any source of  

  heat. Also, do not install the system near any device or  

  break out area that would be adversely effected by water.
• 

 IF

 water hammer is evident, install water hammer arrestors 

before the OneFlow

®

 unit. 

•   Always back-up valves and fittings with a wrench when  

installing a fitting to avoid turning the valve.

Position the OneFlow

®

 unit in a suitable location. 

Iron and Manganese

Just as with conventional water softening media, OneFlow

®

 needs 

to be protected from excess levels of certain metals that can easily 

coat the active surface, reducing its effectiveness over time. Public 

water supplies rarely, if ever, present a problem, but if the water 

supply is from a private well, confirm that the levels of iron (Fe) and 

manganese (Mn) are less than 0.3 mg/L and 0.05 mg/L respec-

tively.

Using OneFlow

®

 with other water treatment 

equipment.

Due to the unique properties of OneFlow

®

, there are some 

unique requirements for using OneFlow

®

 in conjunction with 

filtration or other forms of water treatment.
1.   OneFlow

®

 must be the last stage in the treatment chain. Do 

not install any filters after OneFlow

®

 or before any devices 

for which scale prevention is required. POU filters, e.g. car-

bon or RO are exempt from this requirement.

2.  Do not apply phosphate or any other antiscalant either 

before or after OneFlow

®

.

3.  The addition of soaps, chemicals, or cleaners, before or 

after OneFlow treatment, may reverse its anti-scale treat-

ment effects and/or create water with a heavy residue 

or spotting potential. Any adverse conditions caused by 

the addition of soaps, chemicals, or cleaners are the sole 

responsibility of the end user.

Important notice about iron, manganese and copper in the 

water supply

Copper lines need to be passivized for a minimum of 4 weeks 

before placing unit into service. Not for use on closed loop 

systems.

The OneFlow

®

 system differs from a conventional softener or 

media filter in a number of key respects.
•   The system is light and only partially filled with media. This is 

normal. The upflow operation of the system requires a lot of 

freeboard to allow the bed to fully fluidize.

•   The system has no underbed so you can tip the system 

over without any fear of upsetting the media. This makes 

transportation and installation much easier than conventional 

systems.

•   Because the OneFlow

®

 system operates in the Upflow mode, 

the tank connections are opposite of what you’re used to. 

•   Please see the Important note about iron, manganese and 

copper above.

•   Please see the note about “Using OneFlow

®

 with other 

water treatment equipment” on the next page.

•   Do not let the system freeze. Damage to the tank may 

result.

•   System must be operated in a vertical position. Do not lay 

it down during operation. The system may be placed in any 

position for shipping and installation but must be operated 

in the vertical position.

•   Place the system on a smooth, level surface. Because the 

system operates in an upflow, fluidized bed mode, having a 

level surface is more important than with a softener or media 

filter.

•   A bypass valve should be installed on every system to facili-

tate installation and service.

•   Observe all local plumbing and building codes when install-

ing the system.

WARNING

!

WARNING

!

CAUTION

!

NOTICE

NOTICE

NOTICE

RE: Installation

Copper

Copper usually originates from new copper plumbing upstream 

of the OneFlow

®

 system. If this condition exists, we recommend 

waiting a minimum of 4 weeks before placing the system in 

operation. This will allow the copper surfaces to be fully flushed 

and develop a natural protective surface. To further minimize 

any problem with excess copper, avoid applying excess flux on 

the inner surfaces of the pipe and to use a low-corrosivity water 

soluble flux listed under the ASTM B813 standard. Whenever 

new copper is installed upstream of a OneFlow system, it must 

be bypassed for at least four weeks.
The EPA drinking water standards allow for up to 1.3 ppm of 

copper.  Therefore, it is very important to test the feed water for 

copper.  Oneflow should not be installed if any copper is present 

in the feed water.

Summary of Contents for OneFlow

Page 1: ...aundry and ware washing chemistry will likewise require adjustments OneFlow Benefits Chemical free scale prevention Cost savings and environmental benefits Virtually maintenance free No salt bags or o...

Page 2: ...copper in the water supply Copper lines need to be passivized for a minimum of 4 weeks before placing unit into service Not for use on closed loop systems The OneFlow system differs from a convention...

Page 3: ...65 50 50 GPM at all temperatures OF1665 75 75 GPM at all temperatures Intermittent duty is defined as less than 2 hours of Maximum Flow per 24 hour period Higher Flow rates can be achieved by combinin...

Page 4: ...inlet and outlet bottom and top of the tank It is common for them to loosen during shipment Tighten the bushings with a strap wrench as needed Install Piping Connect the inlet and outlet plumbing acco...

Page 5: ...RIBUTOR SCREEN CUP 5 1 7300423 TANK BUSHING 4 T X 2 SOC W DISTRIBUTOR SCREEN 6 1 7300420 O RING 347 EPDM F PVC HEAD NOT SHOWN 2 C515285 HOSE 2 MX 2 MNPT SF FLEX ASSY 12 LONG SOLD SEPARATELY 1 0002159...

Page 6: ...a el lavado de ropa y piezas tambi n necesitar n ciertos ajustes Ventajas de OneFlow Prevenci n de sarro sin sustancias qu micas Permite ahorrar costos y beneficiar al medio ambiente Pr cticamente no...

Page 7: ...o de OneFlow con otros equipos para tratamiento del agua que se encuentra a continuaci n Precauciones en la instalaci n NO instalar el sistema a una presi n de l nea superior a 100 psi NO instalar el...

Page 8: ...otal y la altura del accesorio de entrada var an seg n las variaciones del material y las tolerancias de montaje Dejar un espacio adicional sobre el dep sito para realizar las conexiones AVISO En el c...

Page 9: ...da y salida parte superior e inferior del dep sito Es normal que se aflojen durante el env o Ajustar los casquillos con una llave de correa seg n sea necesario Instalaci n de las ca er as Conecte las...

Page 10: ...1 7300423 CASQUILLO DE DEP SITO 4 T X 2 SOC CON FILTRO DISTRIBUIDOR 6 1 7300420 JUNTA T RICA N 347 EPDM F CABEZAL PVC 2 C515285 MANGUITO 2 MX 2 MNPT SF FLEX CONJUNTO 12 DE LARGO SE VENDE POR SEPARADO...

Page 11: ...t tre modifi e Avantages du syst me OneFlow Pr vention contre le tartre sans produits chimiques conomies et respect de l environnement Pratiquement sans entretien Pas de sacs de sel ou d autres produi...

Page 12: ...pression de conduite sup rieure 100 psi NE PAS installer le syst me l envers avec la conduite d eau d alimentation raccord e la sortie NE PAS installer le syst me directement la lumi re du soleil et...

Page 13: ...17 b 14 16 c 79 79 d 65 65 e 10 25 10 50 La hauteur hors tout et la hauteur du raccord d entr e varient en fonction des mat riaux et des tol rances d assemblage Pr voir un d gagement suppl mentaire a...

Page 14: ...er les douilles sur l entr e et la sortie en haut et en bas du r servoir Elles se desserrent g n ralement lors du transport Serrer les douilles avec une cl sangle selon le besoin Instalaci n de las ca...

Page 15: ...CM SOC AVEC CRAN DIS TRIBUTEUR 6 1 7300420 JOINT TORIQUE NUM RO 347 EPDM F T TE PVC 2 C515285 TUYAU 2 PO 5 CM MX 2 PO 5 CM MNPT SF FLEX ASSY DE 12 PO 30 CM DE LONG VENDU S PAR MENT 1 0002159 SUPPORT D...

Page 16: ...r the media within two years from date of original installation Such replacement media will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any...