The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. Watts Industries reserves the right to carry out 
any technical and design improvements to its products without prior notice. Warranty: All sales and contracts for sale are expressly conditioned on the buyer’s assent to Watts terms and 
conditions found on its website at www.wattswater.eu. Watts hereby objects to any term, different from or additional to Watts terms, contained in any buyer communication in any form, 
unless agreed to in a writing signed by an officer of Watts.

• 

Do NOT solder plumbing connections attached to filter 
housing will be damaged by high temperature.

• 

Do NOT overtighten fitting connections into housing outlet.

• 

Always back-up valves and fittings with a wrench when 
installing a fitting to avoid turning the valve.

• 

Position the OneFlow unit in a suitable location.

• 

ALLOW a minimum of 8 to 10 cm under the housing to 
allow for filter replacement.

• 

Do NOT install the unit behind equipment where it may be 
difficult to access the system for filter replacement.

• 

If water hammer is evident, install water hammer arrestors 
before the OneFlow unit.

               

      WARNING! 

Installation with copper (Cu)

*** We do not recommend to install OneFlow

®

 with new cop-

per pipes or devices. Excessive copper levels can foul the 
OneFlow

®

 media. If NEW copper lines or devices had been 

installed, they need to be passivated for a minimum of 4 weeks 
before placing the device into service.

               

      WARNING! 

Closed systems/still water

Avoid use in closed circuits (eg hydronic systems) and low 
flow installations or standing water (max. 72 to 120 hours, 
depending on the quality of the incoming water).

• 

Do not apply any other antiscalants before or after OneFlow

®

.

• 

You are required to consult the local building and plumbing 
codes prior to installation. If the information in this manual 
is not consistent with local building or plumbing codes, 
the local codes should be followed. Inquire with governing 
authorities for additional local requirements.

• 

Need for periodic inspection and yearly maintenance:   
Periodic inspection and yearly maintenance by a licensed 
contractor is required. Corrosive water conditions and/or 
unauthorized adjustments or repair could render the device 
ineffective for service intended. Regular checking and clean-
ing of the devices internal components and check stops 
helps assure maximum life and proper product function. 
Frequency of cleaning and inspection depends upon local 
water conditions.

3.2      Installation instructions

1.  Close the water system. Turn off all equipment to be fed by 

the OneFlow

®

 System.

2.  Determine if the water line has an existing water treatment 

system. If so, examine system for use of polyphosphate or 
other scale inhibitors. OneFlow

®

 will not be effective if used 

in conjunction with other scale inhibitors. Remove the scale 
inhibitors from the water line or discontinue installation.

www.watts-oneflow.com/register

4. Operation

With sufficient pressure, operation of the Watts OneFlow

®

 

System is completely automatic. Dependable operation involves 
only periodic cartridge changes and service documentation.

3.  Drill the wall and insert the dowels. Screw the bracket tightly to 

the wall. The system must be vertical and upright.

4.  Remove the OneFlow

®

 housing shell from the housing cap and 

make sure that the O-ring is correctly in place. When attaching 
the shell back to the cap, make certain the O-ring is properly 
positioned.

5.  Connect OneFlow

®

 by using PTFE tape. Use two to three 

wraps of PTFE tape on the fitting connection. 

6.  Run a suitable line from the 

3

/

4

” full-flow ball valve at the 

tap water source to the inlet ball valve on the left side of the 
OneFlow

®

 system. Use 2-3 wraps of PTFE tape and brace the 

inlet ball valve on the system with a wrench when connecting 

7.  Select the appropriate size tubing for the equipment being 

fed and connect it to the outlet of the OneFlow

®

 System. 

NOTE: 

DO NOT connect the tubing to the equipment at this 

time. Prior to making connection to the equipment, this line 
will be used to facilitate flushing the system. As an option, 
a drain valve in a tee on the outlet side of the OneFlow

®

 

system could be provided in the line to facilitate flushing when 
changing cartridges.

8.   With  OneFlow

®

 inlet valve closed, slowly open the 

3

/

4

” full-flow 

ball valve at the tap water source. Check for leaks.

9.    If a drain valve was not installed on the outlet side of the 

system, hold the tubing that will connect to equipment in a 
clean bucket or over sink or drain. Open the system inlet feed 
valve and allow water to flush through system for 2 minutes at 
the specified system flow rate to allow air bubbles to escape.  

NOTE:

 NO ACTIVATION IS REQUIRED FOR THE OneFlow

®

 

SYSTEM TO PERFORM PROPERLY. FLUSHING IS 
RECOMMENDED TO ALLOW AIR TO ESCAPE THE SYSTEM.

10.   Make certain that the end of the tubing to be connected 

to the equipment is clean and sanitary.

11.  Connect tubing to equipment. Open all water supply valves 

and check for leaks.

12.  If no leaks, turn on equipment and check for normal operation.
13.  Register the OneFlow

®

 system to ensure proper operation.

Summary of Contents for OneFlow OFTWH-R

Page 1: ...Watts Oneflow com OneFlow OFTWH R OFTWH Innovative Scale Control Installation manual Installation and Operation Manual UK OFTWH R OFTWH...

Page 2: ...lure to read and follow all safety and use information can result in serious personal injury property damage or damage to the equipment This manual contains important operation maintenance and precaut...

Page 3: ...ment salt free without additional chemicals Improves efficiency of all water heating devices and down stream plumbing components Simple sizing installation standard 3 4 connections Perfect solution fo...

Page 4: ...ts pH 6 5 8 5 Hardness maximum 427 mg l CaCO3 28 8 dH 51 3 fH Water Pressure 1 03 6 2 bar Temperature 5 38 C Free Chlorine 2 mg l Iron maximum 0 3 mg l Manganese maximum 0 05 mg l Copper 1 3 mg l Oil...

Page 5: ...proper product function Frequency of cleaning and inspection depends upon local water conditions 3 2 Installation instructions 1 Close the water system Turn off all equipment to be fed by the OneFlow...

Page 6: ...certifications and may compromise equipment protection water quality and equipment life Cartridge replacement procedure 1 IMPORTANT All other equipment connected to the OneFlow system must be turned...

Page 7: ...rior notice Warranty All sales and contracts for sale are expressly conditioned on the buyer s assent to Watts terms and conditions found on its website at www wattswater eu Watts hereby objects to an...

Page 8: ...ax 49 0 6341 9656 560 www wattswater de Belgium The Netherlands Luxemburg Watts Benelux Beernemsteenweg 77A 8750 Wingene Belgium tel 32 51658708 fax 32 51658720 www wattswater eu Denmark Sweden Finlan...

Reviews: