background image

Limited Warranty

•   The  OneFlow

®

 tank system is warranted to be free of defects in materials and workmanship for 5 years from the date of original shipment.

•   The  OneFlow

®

 media is warranted for performance for a period of 2 years from the date of the original installation when installed and 

operated in accordance with the instructions in the corresponding Installation and Operation Manual.

Watts Regulator Company warrants its OneFlow

®

 cartridge systems as follows:

•   The  OneFlow

®

 cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original 

shipment.

•   OneFlow

®

 cartridges are warranted for performance for a period of one year from the date of original installation when installed and 

operated in accordance with the instructions in the corresponding Installation and Operation Manual.

•   Carbon replacement filter cartridges are not warranted to perform for any period of time because the service life of replacement carbon 

filter cartridges varies significantly with local water conditions and volume.

Conditions

1.   The  OneFlow

®

 system must be installed in applications with municipally supplied water adhering to EPA guidelines. 

2.  Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation.
3.  Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.
4.  Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.
5.   Water supply must not exceed 2.0 PPM chlorine.  For water supply exceeding 2.0 PPM chlorine, pretreatment is required. 

(Please contact your water treatment specialist.)

6.   Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in 

warranty.

7.   Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of 

warranty adjustment is made.

8.   Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value 

and of then current production.

Limitations

Our obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any 

part or parts to our satisfaction that prove defective within the warranty period stated above.  Such replacement parts will be delivered to the 

owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.
Our obligation under this warranty with respect to the OneFlow

®

 media will be limited to furnishing a replacement for the media within two 

years from date of original installation.  Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding 

freight and local labor charges, if any.  Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or 

any other operation outside of the limits shown under Specifications, is not covered by this warranty.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY 

WITH RESPECT TO THE PRODUCT.  WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED.  WATTS 

REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  
The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator 

Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost 

profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting 

from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or 

any other circumstances over which Watts Regulator Company has no control.  This warranty shall be invalidated by any abuse, misuse, 

misapplication or improper installation of the product.  
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of 

incidental or consequential damages.  Therefore the above limitations may not apply to you.  This warranty gives you specific legal rights, and 

you may have other rights that vary from state to state.  You should consult applicable state laws to determine your rights.  SO FAR AS IS 

CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE 

WARRANTY PERIODS STATED ABOVE.

IOM-OF744/844/948/1054   1848 

EDP#1915998 

© 2018 Watts

USA:

  T: (978) 689-6066 • F: (978) 975-8350 • Watts.com

Canada:  

T: (905) 332-4090 • F: (905) 332-7068 • Watts.ca

Latin America:  

T: (52) 81-1001-8600 • Watts.com

Summary of Contents for OneFlow OF744-10

Page 1: ...free scale prevention and protection converts hardness minerals to harmless inactive microscopic crystals making OneFlow an effective alternative technology to a water softener for the prevention of...

Page 2: ...stream to protect specific equipment or areas within a plumbing system The system shall be plumbed with a bypass valve to allow isolation of tank s and to allow the bypass of untreated water in the ev...

Page 3: ...han 0 3 mg L and 0 05 mg L respectively Copper Pursuant to the EPA drinking water standards the maximum copper concentration permitted is up to 1 3 ppm Copper usually originates from new copper plumbi...

Page 4: ...um relief valve is 0556031 not included The vacuum relief valve should be installed on the outlet of the system NOTICE Install Piping Connect the inlet and outlet plumbing according to your preference...

Page 5: ...objects If this threatens the safety value structure or appearance of these objects protect remove them or use the outlet hose to drain option 6 Connect the outlet of the OneFlow system to the cold w...

Page 6: ...you let the whole pipe hose fill with media it will plug up You need to let slugs of water flush out the pipe as you go 12 When all the old media is removed turn off the garden hose and continue to si...

Page 7: ...Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any Our obligation under this warranty with respect to the OneFlow...

Page 8: ...contra el sarro libre de qu micos convierte los minerales duros en cristales microsc picos inactivos e inocuos lo que hace del sistema OneFlow una tecnolog a alternativa efectiva a los ablandadores de...

Page 9: ...ebe conectarse con una v lvula de derivaci n que permite el aislamiento del de los tanque s y para permitir la derivaci n del agua no tratada en el caso de que sea necesario el servicio o el reemplazo...

Page 10: ...la EPA la concentraci n m xima de cobre permitida es de hasta 1 3 ppm Generalmente el cobre proviene de la corriente arriba de la nueva ca er a de cobre del sistema OneFlow y los altos niveles de cob...

Page 11: ...erencias y cualquier reglamento local aplicable Incluya puertos de muestreo drenaje con conexiones de grifo de manguera en las tuber as de entrada y salida para facilitar el arranque y el servicio Rec...

Page 12: ...o ret relos o conecte la manguera a la salida como nica opci n de drenaje 6 Conecte la salida del sistema OneFlow al suministro de agua fr a del edificio 7 Abra la v lvula de suministro del sistema On...

Page 13: ...manguera ca er a se llene de regenerador se producir una obstrucci n Debe dejar que corra agua de la ca er a a medida que avanza 12 Cuando se elimina todo el regenerador apague la manguera de jard n...

Page 14: ...n a la f brica F O B m s cercana del due o sin costo alguno excluyendo cargos por fletes y trabajos locales de presentarse Nuestra obligaci n seg n la presente garant a con respecto al regenerador de...

Page 15: ...chimiques convertit les min raux responsables de la duret en cristaux microscopiques inactifs sans danger rendant la technologie OneFlow un choix de rechange efficace par rapport un adoucisseur d eau...

Page 16: ...s de duret d eau L installation d un syst me peut galement se faire plus en aval pour prot ger des quipements sp cifiques ou des zones du syst me de plomberie Le syst me doit tre install avec une vann...

Page 17: ...potable la concentration maximum de cuivre autoris e ne doit pas d passer 1 3 ppm Le cuivre provient habituellement de plomberie en cuivre en amont du syst me OneFlow et des niveaux lev s de cuivre en...

Page 18: ...le respect de tout code local applicable Incluez des raccords d chantillon d vacuation avec des connexions de robinet d arrosage sur la tuyauterie d entr e et de sortie afin de faciliter le d marrage...

Page 19: ...u de sortie pour l coulement 6 Raccordez la sortie du syst me OneFlow au tuyau d arriv e d eau froide de l difice 7 Ouvrez le robinet d alimentation en direction du syst me OneFlow 8 Ouvrez les robine...

Page 20: ...s laissez l ensemble tuyau tuyau de remplissage avec les m dias il se bloquera Vous devez laisser les jets d eau sortir du tuyau 12 Lorsque tous les anciens m dias sont enlev s fermez le tuyau d arros...

Page 21: ...ion qui se r v le r v lent d fectueuse s pendant la p riode de garantie indiqu e ci dessus Ces pi ces de rechange seront livr es au propri taire FAB l usine la plus proche sans frais l exclusion des f...

Reviews: