background image

Installation, Operation and 
Maintenance Manual

OneFlow

®

 Anti-Scale System

Chemical-Free, Salt-Free Scale Prevention

Model OF744-10
Model OF844-12

IOM-OF744/844/948/1054

Systems are certified through WQA 

against NSF/ANSI Standards 61 and 372 

for Lead Free compliance.

Introduction

The Watts OneFlow

®

 Anti-Scale System provides protection 

from scale formation on internal plumbing surfaces. The 

OneFlow

®

 system can be installed at the point of entry to a 

building to treat both hot and cold water, or it can be located 

directly before a water heater, boiler, or other water using 

device that requires protection from hard water.
OneFlow

®

 prevents scale by transforming the normal dissolved 

hardness minerals into undissolved crystal microparticles. 

These crystals stay suspended in the water and have a greatly 

reduced ability to react and attach to surfaces like dissolved 

hardness does. Therefore the problem of internal buildup 

of scale in pipes, water heaters and on fixtures and glass is 

greatly reduced.
OneFlow

®

 is not a water softener or a chemical additive (like 

anti-scalants or sequestrants). It is a scale prevention device 

with proven third party laboratory test data and years of 

successful residential and commercial installation. OneFlow® 

is the one water treatment device that effectively provides scale 

protection and is a great salt-free alternative to water softening 

(ion exchange) or scale sequestering chemicals. Laundry and 

warewashing chemistry will likewise require adjustments.

OneFlow

®

 Benefits

•   Chemical-free scale prevention and protection – converts 

hardness minerals to harmless, inactive microscopic crystals 

making OneFlow

®

 an effective alternative technology to 

a water softener for the prevention of scale due to water 

hardness

•  Virtually maintenance free - no control valve
•   Uses environmentally friendly technology by using no salt 

or other chemicals to constantly add, no electricity and no 

wastewater

•   Improves efficiency of all water using appliances – both hot** 

and cold

•   Simple sizing & installation – all you need to know is pipe 

size and the peak flow rate.

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information 

can result in death, serious personal injury, property 

damage, or damage to the equipment.
Keep this Manual for future reference.

Do not use with water that is microbiologically unsafe or of 

unknown quality without adequate disinfection before or after the 

system.

WARNING

!

•   Safe for landscaping and lawn watering. No need for costly 

bypass plumbing.

•   Compatible with all on-site and community wastewater 

treatment systems.

•   Perfect system for towns or communities where water 

softeners are banned or restricted

•   OneFlow

®

 does not remove minerals or add sodium to the 

water supply

•   OneFlow can be installed as pre-treatment to commercial 

reverse osmosis systems (contact your Watts Representative 

for further details)

*   For high-flow applications, contact your Watts Representative 

for details on larger, multi-tank systems plumbed in parallel 

that can meet high flow applications from 100 gpm to and 

above 1000 gpm

**  For hot water applications where feed water temperature is 

100°F – 140°F (38° – 60°C), please consult ES-OneFlow-

HotWater.

Model OF948-16
Model OF1054-20

Summary of Contents for OneFlow OF744-10

Page 1: ...free scale prevention and protection converts hardness minerals to harmless inactive microscopic crystals making OneFlow an effective alternative technology to a water softener for the prevention of...

Page 2: ...stream to protect specific equipment or areas within a plumbing system The system shall be plumbed with a bypass valve to allow isolation of tank s and to allow the bypass of untreated water in the ev...

Page 3: ...han 0 3 mg L and 0 05 mg L respectively Copper Pursuant to the EPA drinking water standards the maximum copper concentration permitted is up to 1 3 ppm Copper usually originates from new copper plumbi...

Page 4: ...um relief valve is 0556031 not included The vacuum relief valve should be installed on the outlet of the system NOTICE Install Piping Connect the inlet and outlet plumbing according to your preference...

Page 5: ...objects If this threatens the safety value structure or appearance of these objects protect remove them or use the outlet hose to drain option 6 Connect the outlet of the OneFlow system to the cold w...

Page 6: ...you let the whole pipe hose fill with media it will plug up You need to let slugs of water flush out the pipe as you go 12 When all the old media is removed turn off the garden hose and continue to si...

Page 7: ...Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any Our obligation under this warranty with respect to the OneFlow...

Page 8: ...contra el sarro libre de qu micos convierte los minerales duros en cristales microsc picos inactivos e inocuos lo que hace del sistema OneFlow una tecnolog a alternativa efectiva a los ablandadores de...

Page 9: ...ebe conectarse con una v lvula de derivaci n que permite el aislamiento del de los tanque s y para permitir la derivaci n del agua no tratada en el caso de que sea necesario el servicio o el reemplazo...

Page 10: ...la EPA la concentraci n m xima de cobre permitida es de hasta 1 3 ppm Generalmente el cobre proviene de la corriente arriba de la nueva ca er a de cobre del sistema OneFlow y los altos niveles de cob...

Page 11: ...erencias y cualquier reglamento local aplicable Incluya puertos de muestreo drenaje con conexiones de grifo de manguera en las tuber as de entrada y salida para facilitar el arranque y el servicio Rec...

Page 12: ...o ret relos o conecte la manguera a la salida como nica opci n de drenaje 6 Conecte la salida del sistema OneFlow al suministro de agua fr a del edificio 7 Abra la v lvula de suministro del sistema On...

Page 13: ...manguera ca er a se llene de regenerador se producir una obstrucci n Debe dejar que corra agua de la ca er a a medida que avanza 12 Cuando se elimina todo el regenerador apague la manguera de jard n...

Page 14: ...n a la f brica F O B m s cercana del due o sin costo alguno excluyendo cargos por fletes y trabajos locales de presentarse Nuestra obligaci n seg n la presente garant a con respecto al regenerador de...

Page 15: ...chimiques convertit les min raux responsables de la duret en cristaux microscopiques inactifs sans danger rendant la technologie OneFlow un choix de rechange efficace par rapport un adoucisseur d eau...

Page 16: ...s de duret d eau L installation d un syst me peut galement se faire plus en aval pour prot ger des quipements sp cifiques ou des zones du syst me de plomberie Le syst me doit tre install avec une vann...

Page 17: ...potable la concentration maximum de cuivre autoris e ne doit pas d passer 1 3 ppm Le cuivre provient habituellement de plomberie en cuivre en amont du syst me OneFlow et des niveaux lev s de cuivre en...

Page 18: ...le respect de tout code local applicable Incluez des raccords d chantillon d vacuation avec des connexions de robinet d arrosage sur la tuyauterie d entr e et de sortie afin de faciliter le d marrage...

Page 19: ...u de sortie pour l coulement 6 Raccordez la sortie du syst me OneFlow au tuyau d arriv e d eau froide de l difice 7 Ouvrez le robinet d alimentation en direction du syst me OneFlow 8 Ouvrez les robine...

Page 20: ...s laissez l ensemble tuyau tuyau de remplissage avec les m dias il se bloquera Vous devez laisser les jets d eau sortir du tuyau 12 Lorsque tous les anciens m dias sont enlev s fermez le tuyau d arros...

Page 21: ...ion qui se r v le r v lent d fectueuse s pendant la p riode de garantie indiqu e ci dessus Ces pi ces de rechange seront livr es au propri taire FAB l usine la plus proche sans frais l exclusion des f...