Feed Water Chemistry Requirements

pH

6.5-8.5

Hardness (maximum)

75 grains (1282 ppm CaCO3)

Water Pressure

15psi to 100psi (1.03 bar to 6.9 bar)

Temperature

40°F to 110°F (5°C to 43°C)

Free Chlorine

< 2 ppm

Iron (maximum)

0.3 ppm

Manganese (maximum) 0.05 ppm

Copper

1.3 ppm*

Oil & H2S

Must be Removed Prior to OneFlow

Polyphosphates

Must be Removed Prior to OneFlow

Silca (maximum)

20 ppm**

WARNING

!

Installation Precautions

•   Do 

NOT

 install system on line pressure above 100psi.

•   Do 

NOT

 install system on HOT water line. Failure to limit line 

temperature to 110°F/43°C may result in housing failure and 

damage.

•   Do 

NOT

 install the system backwards with the feed water 

line connected to the outlet.

•   Do 

NOT

 use liquid pipe compounds for fitting connections. 

USE two to three wraps of Teflon® tape.

•   Do 

NOT

 solder plumbing connections attached to filter 

housing or inlet valve. Inlet valve and filter housing will be 

damaged by high temperature.

•   Do 

NOT

 allow system to freeze. Turn off water supply to 

housing and drain housing if temperature falls below 32°F.

•   Do 

NOT

 install system in direct sunlight or where system is 

exposed to harsh chemicals or may be subjected to being 

struck by moving equipment, carts, mops or any other 

item that may cause damage.

• 

 ALLOW

 a minimum of 3" under the housing to allow for 

filter replacement.

•   IF water hammer is evident, install water hammer arrestors 

before the OneFlow

®

 unit. 

•   Do 

NOT

 overtighten fitting connections into inlet valve or 

housing outlet. 

•   Always back-up valves and fittings with a wrench when 

installing a fitting to avoid turning the valve.

•   Do 

NOT

 install the unit behind equipment where it may be dif-

ficult to access the system for filter replacement.

Position the OneFlow

®

 unit in a suitable location. The direction 

of flow through the OneFlow

®

 unit is always left to right; keep 

this in mind when determining installation location. Do NOT 

mount the OneFlow

®

 system near any source of heat. Also, 

do not mount the system above any device or area that would 

be adversely affected by water. 

WARNING

!

*High levels of Copper will foul OneFlow media and typically 

originates from new Copper plumbing. Wait a minimum of 

4 weeks before placing system in operation. Avoid apply-

ing excess flux on the inner surfaces of the pipe and to use 

a low-corrosivity water soluble flux listed under the ASTM 

B813 standard.

NOTICE

** OneFlow media does not reduce silica scaling. Silica can act 

as a binder that makes water spots and scale residue outside 

the plumbing system difficult to remove. This 20 ppm limita-

tion is for aesthetic purposes.

•   Connect system to cold water supply only. Water temperature 

cannot exceed 110°F/43°C.

•  System 

must be

 installed in a vertical, upright and level position.

•   OneFlow

®

 systems 

must not

 be used in conjunction with 

polyphosphate or any other scale inhibitor.

•   Do not use with water that is microbiologically unsafe or of 

unknown quality without adequate disinfection before or after 

the system.

WARNING

!

Summary of Contents for OneFlow OF110

Page 1: ...ve a grain removal capacity however other contaminants present in the water will gradually degrade the effectiveness of this cartridge Change the OF110RM cartridge at least once a year IOM OF110 1 WAR...

Page 2: ...e the OneFlow unit Do NOT overtighten fitting connections into inlet valve or housing outlet Always back up valves and fittings with a wrench when installing a fitting to avoid turning the valve Do NO...

Page 3: ...e tubing to the equipment at this time Prior to making connection to the equipment this line will be used to facilitate flushing the system As an option a drain valve in a tee on the outlet side of th...

Page 4: ...4 Installation Drawings Dimensions N I...

Page 5: ...housing if equipped and flush the new cartridges to drain or bucket for two 2 minutes or until water runs clear If no flush valve is present disconnect line from equipment to flush to drain 10 With wa...

Page 6: ...6 Replacement Parts for OneFlow OF110 1 Drawing ID Description 1 Housing 1 2 10 w PR 1a O Ring 2 Valve 1 2 FxM Ball 3 Bracket Single Housing 4 OF110RM Replacement Cartridge 5 Screws 1a...

Page 7: ...acement parts will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any Our obligation under this warranty with respect to the OneFlow media will...

Page 8: ......

Page 9: ...go otros contaminantes presentes en el agua degradar n la eficacia de este cartucho en forma gradual Cambiar el cartucho OF110RM al menos una vez por a o IOM OF110 1_ES ADVERTENCIA Lea este manual ANT...

Page 10: ...cuado La direcci n del caudal que pasa por la unidad OneFlow siempre es de izquierda a derecha Tener en cuenta este factor al determinar el lugar de instalaci n NO montar el sistema OneFlow cerca de n...

Page 11: ...OneFlow NOTA NO conectar la tuber a al equipo a n Antes de realizar la conexi n al equipo esta tuber a se utilizar para ayudar a purgar el sistema Como pieza opcional se puede proporcionar para la tub...

Page 12: ...N DE AGUA DEBE INSTALARSE NICAMENTE EN EL SUMINISTRO DE AGUA FR A PRESI N M X 125 psi TEMPERATURA M X 100 F LA UNIDAD DE FILTRACI N DE AGUA DEBE INSTALARSE NICAMENTE EN EL SUMINISTRO DE AGUA FR A MONT...

Page 13: ...te desde el alojamiento del filtro si corresponde y purgar los cartuchos nuevos al desag e o a un cubo durante dos 2 minutos o hasta que el agua salga transparente Si no hay una v lvula de purga desco...

Page 14: ...esto para OneFlow OF110 1 N de referencia del diagrama Descripci n 1 Alojamiento 1 2 N 10 con PR 1a Junta t rica 2 V lvula esf rica de 1 2 FxM 3 Soporte alojamiento simple 4 Cartucho de repuesto OF110...

Page 15: ...er n entregadas al propietario bajo condici n Libre a bordo Free on Board FOB en la f brica m s cercana sin costo alguno sin incluir gastos de flete y mano de obra local de corresponder Nuestra obliga...

Page 16: ......

Page 17: ...acit de retrait des grains De plus d autres contaminants pr sents dans l eau r duiront petit petit l efficacit de la cartouche Remplacer la cartouche OF110RM au moins une fois par an IOM OF110 1_FR AV...

Page 18: ...ection de l coulement par l unit OneFlow se fait toujours de gauche droite garder ceci l esprit lors de la s lection de l emplacement NE PAS monter le syst me OneFlow pr s d une source de chaleur De m...

Page 19: ...terie l quipement ce stade Avant d effectuer un raccordement l quipement cette conduite sera utilis e pour faciliter le rin age du syst me En option un robinet de vidange dans un t sur le c t de sorti...

Page 20: ...SSAGE INT GRAL D 1 2 PO VERS ALIMENTATION EN EAU FROIDE 3 PO MIN D GAGEMENT POUR LE RETRAIT HAUTEUR D INSTALLATION 2 PI ET 8 PO MIN 5 PI ET 0 PO AU DESSUS DU SOL FINI 2 7 8 PO MUR PRESSION MAX 125 psi...

Page 21: ...rtouches neuves au dessus d une vacuation ou d un seau pendant deux 2 minutes ou jusqu ce que l eau qui s coule soit propre S il n y a pas de robinet de rin age s pa rer la conduite de l quipement pou...

Page 22: ...ange pour OneFlow OF110 1 N de sch ma Description 1 Bo tier 1 2 po n 10 avec limiteur de pression 1a Joint torique 2 Robinet bille d 1 2 po FxM 3 Support de bo tier unique 4 Cartouche de remplacement...

Page 23: ...des frais de transport et de main d uvre locale le cas ch ant Notre obligation dans le cadre de cette garantie par rapport au m dia filtrant OneFlow sera limit e son remplacement dans les deux ann es...

Page 24: ...Notes Notas Notes...

Reviews: