LYNC UV-H
SECTION 3: PRODUCT SPECIFICATIONS
•
•
•
Reuse and Waste Water
Lync UV-H Models
Hallett
1000W
Hallett
1000R
Hallett
750W
Hallett
750R
Hallett
500W
Hallett
500R
Default Flow Rate
1
70 gpm
70 gpm
18 gpm
13 gpm
14 gpm
10 gpm
Performance Certifications
2
NWRI
NWRI
Min. UVT
1
77%
77%
50%
50%
50%
50%
Flow Restrictor
Optional
Optional
Optional
Optional
Optional
Optional
Pressure Drop
3
2.6 psi
2.6 psi
2.8 psi
1.4 psi
1.6 psi
0.8 psi
Lamp Type
Amalgam
Amalgam
LPHO
LPHO
LPHO
LPHO
Lamp Life
4
16 months
16 months
12 months
12 months
12 months
12 months
Cycles/day
5
6-12
6-12
2 (I.S.)
6-12 (P.H.)
2 (I.S.)
6-12 (P.H.)
2 (I.S.)
6-12 (P.H.)
2 (I.S.)
6-12 (P.H.)
UV Sensor
Quad
Quad
Dual
Dual
Dual
Dual
Built-in Purge Valve
Standard
Standard
Standard
Standard
Standard
Standard
Automatic Quartz Sleeve Cleaning Device
Standard
Standard
Standard
Standard
Standard
Standard
Wiper Position Switch
Standard
Standard
Standard
Standard
Standard
Standard
Lamp Heaters
No
No
Standard
Standard
Standard
Standard
4-20mA Output
Optional
Optional
Optional
Optional
Optional
Optional
Modbus connectivity
Optional
Optional
Optional
Optional
Optional
Optional
Power Draw
403W
403W
222W
222W
196W
196W
Inlet & Outlet Port size
2" MNPT
2" MNPT
1" MNPT
1" MNPT
1" MNPT
1" MNPT
Nominal Dimensions
(H x W x D)
56x11x9"
(142x29x
22cm)
56x11x9"
(142x29x
22cm)
40x10x9"
(103x24x
22cm)
40x10x9"
(103x24x
22cm)
36x10x9"
(93x24x
22cm)
36x10x9"
(93x24x
22cm)
1
The maximum flow of the unit will depend on various parameters such as UVT, TSS, and level of UV dose required. The UV-H Hallett 1000W
and Hallett 1000R are capable of specific flow and UVT configurations. The peak flow & min. UVT for the unit is indicated in the proposal
document. The Hallett 750W, 750R, 500W and 500R can be configured to high or low UVT applications by service technicians.
2
The Hallett 1000W and Hallett 1000R are NWRI validated between 19-150mJ/cm
2
. Third party validations are pending.
3
Values presented are without the flow restrictor. The flow restrictor adds significant pressure drop.
4
Amalgam lamp lifetime is 12,000hrs/500 days and LPHO lifetime is 9000hrs/375 days
5
Instant Start (I.S.) LPHO limited to 2 cycles/day; Preheat (P.H.) models have 6-12 cycles/day. Exceeding the recommended daily cycles will
accelerate the age of the UV lamps. LPHO lamps perform more reliably when operated 24/7.