LYNC UV-H
SECTION 3: PRODUCT SPECIFICATIONS
•
•
•
SECTION 3: PRODUCT SPECIFICATIONS
Specifications & Features common to all units
Operating Pressure
1
5-100 psig (34-690 kPa)
Water Temperature Range
2
34-104
°
F (1-40
°
C)
Air Temperature Range
2
34-104
°
F (1-40
°
C)
Maximum Relative Humidity
3
70%
Voltage Input
120Vac 50/60Hz for North America.
230 or 240 Vac 50/60Hz for International.
See power input label on left side of unit near power cord.
Manifold materials
316 Stainless Steel
External Contact
2 available - Standard
Remote Start/Stop
Standard
Data Logging to USB Drive
Optional on all units
Automatic Solenoid Shutoff Valve
Optional on all units
Wetted Parts
Meets NSF/ANSI/CAN 61 & NSF/ANSI 372
1
Purging requires pressure to work properly. The optional shutoff valve requires min. 8psig (55kPa) to operate.
2
In extreme conditions, high air temperatures may require lower temperatures for proper operation and vice versa.
3
For continuous flow potable applications, it is recommended to dehumidify the room where the UV unit is located.
4
Certified by WQA to 73
°
F or 23
°
C
Flow restrictors limit the water flow through the UV unit despite the demand or the amount of supply
pressure. A flow restrictor is mandatory for an NSF/ANSI 55 Class A system but optional for other units.
Warning:
Removal of this device may allow the water flow to exceed the validated performance of the
system which therefore may not provide the necessary UV dose for effective treatment.
Potable Water
Lync UV-H Models
Hallett
1000P
Hallett
750PN
Hallett
750P
Hallett
500PN
Hallett
500P
Max. Flow Rate
1
100 gpm
27.4 gpm
40 gpm
16.5 gpm
37 gpm
Performance Certifications
2
NSF/ANSI 55
Class A
NSF/ANSI 55 Class
A
Min. UVT for 40mJ/cm
2
Dose
95%
75%
95%
75%
95%
Flow Restrictor
Optional
Yes
Optional
Yes
Optional
Pressure Drop
5 psi
22.7 psi
3
13 psi
22.7 psi
4
10 psi
Lamp Type
Amalgam
LPHO
LPHO
LPHO
LPHO
Lamp Life
5
16 months
12 months
12 months
12 months
12 months
Cycles/day
6
6-12
2 (I.S.)
6-12 (P.H.)
2 (I.S.)
6-12 (P.H.)
2 (I.S.)
6-12 (P.H.)
2 (I.S.)
6-12 (P.H.)
UV Sensor
Quad
Dual
Dual
Dual
Dual
Built-in Purge Valve
Standard
Standard
Standard
Standard
Standard
Automatic Quartz Sleeve Cleaning Device
Standard
Standard
Standard
Standard
Standard
Wiper Position Switch
Standard
Standard
Standard
Standard
Standard
Lamp Heaters
No
Standard
Standard
Standard
Standard
4-20mA Output
Optional
Optional
Optional
Optional
Optional
Modbus connectivity
Optional
Optional
Optional
Optional
Optional
Power Draw
403W
222W
222W
196W
196W
Inlet & Outlet Port size
2" MNPT
1" MNPT
1" MNPT
1" MNPT
1" MNPT
Nominal Dimensions
(H x W x D)
56x11x9"
(142x29x 22cm)
40x10x9"
(103x24x 22cm)
40x10x9"
(103x24x 22cm)
36x10x9" (93x24x
22cm)
36x10x9"
(93x24x 22cm)
1
Based on UV Dose of 40mJ/cm
2
at alarm setpoint.
2
NSF/ANSI 55 Class A certifications substantiated by NSF International only. Third party validations are pending.
3
The flow restrictor adds significant pressure drop so the value presented is at 75% of maximum flow capacity.
4
The flow restrictor adds significant pressure drop so the value presented is at 75% of maximum flow capacity.
5
Amalgam lamp lifetime is 12,000hrs/500 days and LPHO lifetime is 9000hrs/375 days.
6
Instant Start (I.S.) LPHO limited to 2 cycles/day; Preheat (P.H.) models have 6-12 cycles/day. Exceeding the recommended daily cycles will
accelerate the age of the UV lamps. LPHO lamps perform more reliably when operated 24/7.