SECTION 7: MAINTENANCE
•
•
•
3. When the bottom pins have disengaged the socket, lift the lamp up, then swing the lamp base away
from socket. Lower the lamp to disengage it from the top lamp holder. With the lamp free from the
unit, carefully place it aside and remove the other lamp.
4. Dispose of the old lamps in the same way as ordinary fluorescent tubes. Note that old lamps should
be disposed of at a household waste management depot or transfer station; contact your local
recycling and waste management authority for proper disposal procedures in your area.
Figure 7-3
Figure 7-4
5. Install the new lamps into the unit one at a time, being careful not to touch the bulb. Insert the top
end of the lamp through the top lamp holder then swing lamp base in over the socket. For a LPHO
lamp, rotate it until the
“Stop Sign” symbol printed on the top ceramic is towards the left. See Figure
7.5. For an amalgam lamp, rotate it until the wires running down the lamp are facing the back of the
unit
– a check mark has been added to the top ceramic on same side as the wires. The proper
orientation of the LPHO and amalgam lamp has the lamp wires opposite the UV sensors.
Figure 7-5