Technical Support

  •  (800) 433-5654  •  Mon-Fri, 8 am - 5 pm CST

Equipment Specifications

AquaSolve systems are complete, selfcontained, 
loaded with media, and ready to use. A simple 
inlet and outlet connection is all that is required for 
installation. Please review operating pressures, tem-
peratures and water chemistry limitations to ensure 
compatibility.

Feed Water Chemistry Requirements

Water known to have heavy loads of dirt and debris may require  

pre-filtration prior to AquaSolve.
*Systems using AquaSolve technology are effective at controlling lime-

scale formation inside the plumbing system at influent hardness levels 

up to 75 grains per gallon (1282 mg/l) of calcium carbonate. Due to 

variances in water chemistry, 30 grains per gallon is a recommended 

hardness maximum due to potential aesthetic issues related to soft 

scale residue formation outside of the plumbing system. Testing should 

be performed to determine proper application where hardness levels 

exceed 30 grains per gallon.
**Just as with conventional water softening media, AquaSolve media 

needs to be protected from excess levels of certain metals that can eas-

ily coat the active surface, reducing its effectiveness over time. Public 

water supplies rarely, if ever, present a problem, but if the water supply 

is from a private well, confirm that the levels of iron (Fe) and manga-

nese (Mn) are less than 0.3 mg/L and 0.05 mg/L, respectively.
***Pursuant to the EPA drinking water standards, the copper con-

centration permitted is up to 1.3 ppm. Typically originating from new 

copper plumbing, high levels of copper can foul AquaSolve media. For 

applications with copper concentration greater than 1.3 ppm, please 

consult Lync Systems Engineering. To further minimize any problem 

with excess copper, avoid applying excessive flux on the inner surfaces 

of the pipe and use a low-corrosivity water soluble flux listed under the 

ASTM B813 standard.
****AquaSolve media does not reduce silica scaling. While silica tends 

to have a less significant effect on scale formation than other minerals, 

it can act as a binder that makes water spots and scale residue outside 

the plumbing system difficult to remove. This 20 ppm limitation is for 

aesthetic purposes.

NOTICE

Systems using 

AquaSolve

 technology prevent hard water scale 

formation inside the plumbing system at influent hardness levels 
of 30 grains per gallon of calcium carbonate and less. Due to vari-
ances in water chemistry, certain aesthetic conditions external of 
the plumbing system may not be attained. AquaSolve is designed 
for the treatment of potable water that meets the requirements of 
the current USEPA Safe Drinking Water Act.

NOTICE

Mechanical Specifications

LM8408-COM

LM8410-COM

Dry Weight

36 lbs / 16 kgs

49 lbs / 22 kgs

Service Weight

108 lbs / 49 kgs

182 lbs / 83 kgs

Inlet/Outlet
Connection

1” FNPT

1” FNPT

Max Service 
Flow gpm

12

20

Dimensions 

(inches)

LM8408-COM

LM8410-COM

A

47.5

58.0

B

46.0

56.5

C

11.1

12.0

D

1.5

1.5

E

2.0

2.0

Exceeding maximum flow can reduce effectiveness and void  
warranty. Pressure drop at peak flow rate is less than 14 psi.
Pressure drop reading taken with inlet and outlet gauges installed 
at a common elevation and 80ºF feed water.

pH

6.5-8.5

Hardness (max.)

30 grains (513 ppm CaCO3)*

Water Pressure

15 psi to 150 psi (1.03 to 10.34 bar)

Temperature

40°F to 100°F (5°C to 38°C)

Free Chlorine

< 2 ppm

Iron (maximum)

0.3 ppm**

Manganese (max.)

0.05 ppm**

Copper (max.)

1.3 ppm***

Oil & H2S

Must be Removed Prior to AquaSolve

Total Phosphates 

< 3.0 ppm

Silica (max.)

20 ppm****

TDS

< 1500 mg/l*****

*****All other contaminants must meet the requirements of the USEPA 

Safe Drinking Water Act. Specific Mineral and Metal MCL’s, identified in 

Watts published Feed Water Chemistry Requirements, supersedes the 

USEPA SDWA.

Operation & Maintenance Manual

Lync AquaSolve

Summary of Contents for Lync AquaSolve LM8408-COM

Page 1: ...rth TX 76134 817 335 9531 Technical Support 800 433 5654 ext 3 Mon Fri 8 am 5 pm CST Engineered Solutions OMM LM8408_LM8410 COM_EN Important Read this Manual BEFORE using this equipment Failure to rea...

Page 2: ...effec tive alternative technology to a water softener for the prevention of scale due to water hardness Virtually maintenance free no control valve Uses environmentally friendly technology by using no...

Page 3: ...AquaSolve in conjunction with other forms of water treatment 1 AquaSolve must be the last stage in the treatment chain Do not install any filters after AquaSolve or before any devices for which scale...

Page 4: ...pplying excessive flux on the inner surfaces of the pipe and use a low corrosivity water soluble flux listed under the ASTM B813 standard AquaSolve media does not reduce silica scaling While silica te...

Page 5: ...needed for servicing The full weight of the plumbing system must be supported by pipe hangers or other means NOTICE Install Piping Connect the inlet and outlet plumbing according to your preferences a...

Page 6: ...lue structure or appearance of these objects protect remove them or use the outlet hose to drain option 7 Connect the outlet of the AquaSolve system to the cold water supply to the building Install an...

Page 7: ...pe hose fill with media it will plug up You need to let slugs of water flush out the pipe as you go Your AquaSolve media should be replaced every 3 years Dispose of old media and or container in accor...

Page 8: ...F O B nearest factory at no cost excluding freight and local labor charges if any Our obligation under this warranty with respect to the Lync AquaSolve media will be limited to furnishing a replaceme...

Reviews: