background image

Rods run through

cabinet @ all four 

corners.

Nylon lock nuts & flat washers

lock rods at top & bottom

of M-200 enclosure

Threaded rods attached to ceiling

Threaded Rod

Flat Washer

Nylon Lock Nut

Metal or wood stud

Rear panel

Mounting holes

for stud attachment

on 18”  or 16” centers

18”

16”

Bottom panel

California Code requires

four sizemic mounting holes

for floor attachment

Equipment 

Outlet

(Product Water)

Drain

Outlet

Tapwater

Inlet

Air Tank 

Access

Four Adjustable

Leveler Feet

NOTE:

Need access to front panel and 

right side “Air Tank Access Cap” .

Recommended:

Front Panel Access - 18” clearance

Side Panel Access - 12” clearnace

Panel 

Cover

ACCESS

AREA

ACCESS

AREA

18”

24”

16”

20-1/4”

12”

17.876

2.063

16.36

3.062

1.95

%%c

.50

20.25

Rear View

E

E

E

E

E

E

2

5

3

6

1

4

24.00

14.00

22.00

9.50

9.50

2.50

1.00

1.09

%%c

.50

Top View

A

D

D

D

D

2

3

4

1

B

C

%%c

2.50

6.3

5.94

Side View

10.94

10.94

1.062

7.00

7.00

%%c

.375

Bottom View

G

G

G

G

1

2

3

4

D

C

3

4

B

D

E

F

DWG NO.

REVISION

DO NOT SCALE DRAWING

WEIGHT:

MATERIAL:

DATE

NAME

Q.A

DRAWN

1

2

E

D

A

B

C

2

1

4

3

C

3

4

B

D

E

F

DWG NO.

REVISION

DO NOT SCALE DRAWING

WEIGHT:

MATERIAL:

DATE

NAME

Q.A

DRAWN

1

2

E

D

A

B

C

2

1

4

3

TAPWATER

INLET

EQUIPMENT

OUTLET

DRAIN

OUTLET

PERM

IN

PERM

IN

BRINE

IN

BRINE

OUT

BRINE

OUT

BRINE

OUT

BRINE

IN

BRINE

IN

PERM

OUT

PERM

OUT

PERM

OUT

PERM

IN

PERM

IN

1

9

2

3

10

5

5

5

4

4

4

6

6

6

7

8

X

GREEN TUBING

BLACK TUBING

BLACK >

BLACK >

BLACK TUBING

BLACK

BLACK

BLUE

BLUE

BLUE

BLUE

BLUE

BLUE

BLACK

BLACK TUBING

BLACK TUBING

BLACK TUBING

E4

E2

E1

E3

A

A

ITEM

ITEM

DESCRIPTION

PART NUMBER

1

2

3

4

5

6

7

8

9

10

10

A

B

C

D

D1-D4

E1-E4

H1-H6

G1-G4

G1-G4

107021

107024

101011

210000

222019

152002

219002

307020

234010

134028

5 MICRON SEDIMENT FILTER

           GAC/KDF

10 MICRON CARBON BLOCK

MEMBRANE TFM 100 GPD

750 ML FLOW RESTRICTOR

PERMEATE PUMP WITH CLIP

PRESSURE TANK

ALL CALCITE

1/2” BRASS CHECK VALVE

1/2” BY PASS VALVE

ON UNIT CONNECTION             SIZE                          APPROVED MATERIAL

PERMEATE WATER TO BOILER                               

DRAIN WATER CONNECTION                             

INLET “COLD” WATER CONNECTION                               

AIR TANK ACCESS                              

           MOUNTING LOCATION

                              

CEILING MOUNT ( TOP PANEL )                              

CEILING MOUNT ( BOTTOM PANEL )                         

WALL MOUNT                             

FLOOR MOUNT                               

FLOOR MOUNT FOR SEISMIC STATES                              

1/2” FPT

1/2” FPT

1/2” FPT

2 1/2” OPENING

SIZE

3/8”

3/8”

3/8”

3/8”

3/8”

         1/2” L COPPER ( SWEAT OR FLAIR )

         1/2” L COPPER/PVC/POLY PROPYLENE 

         1/2” L COPPER/PVC/POLY PROPYLENE

TIRE PRESSURE GAUGE 0-50 PSI RANGE

         APPROVED MATERIAL

             THREADED STOCK  

             THREADED STOCK  

             5/16” X 2 1/2” 

             LEG GUIDE ( PROVIDED )/HILTI 

             HILTI ANCHORS (3/8” X 3 1/2” ) 

 304 Stainless Steel

 77 LBS 

 304 Stainless Steel

M-200-1

7/15/02

A1

TITLE: M-200 BoilerMate

7/18/02

7/18/02

7/18/02

7/18/02

ENG.

PROD.

SALES

A2

TITLE: M-200 BoilerMate

 M-200-1

7/15/02

ENG.

PROD.

SALES

7/18/02

7/18/02

7/18/02

7/18/02

7/18/02

77 LBS

NELSON A.

SCHMITT C.

HENSS M.

HANFORD J.

MANGIN P.

NELSON A.

SCHMITT  C.

HENSS M.

HANFORD J.

MANGIN P.

7/18/02

Summary of Contents for HS-200 PT

Page 1: ...ent Increased reliability fewer equipment breakdowns due to boiler scaling Convenient quarterly maintenance intervals with economical PM packages available SPECIFICATIONS Provides 5 50 TDS output water from potable water sources up to 2000 TDS 250 ppm or 14 grains hardness PM package available separately Includes a year s supply of consumable components Watts Modernization Package HS 200 PT Revers...

Page 2: ...degrees F 50 90 psig 2000TDS 250ppm or 14 grains hardness Operation Once all service and output connections are made simply turn on cold water supply to the unit Maintenance Quarterly Replace pre filters items 1 2 3 8 Annually Replace membrane cartridges item 4 Replacement Parts PM Package Part 501020 PM package includes a 1 year supply of Items 1 2 3 4 8 Individual part numbers for component part...

Page 3: ...XIMUM 1200 PPM OR 500mg L NaCl 8 First year preventitive maintenance kit included P N 501020 9 CLEARANCE MINIMUM 18 SERVICE CLEARANCE ON SIDES D C MINIMUM 35 ON SIDE A 10 FLOOR DRAIN REQUIREMENTS MIN 1 2 DIA WITHIN 10 OF PROCESSING UNIT SOURCE OF SUPPLY PROCESSOR P N 570200 MFG Watts Pure Water Phoenix AZ USA 9 50 9 50 24 00 22 00 14 00 16 07 1 50 13 00 16 02 21 15 20 00 24 00 22 00 1 PERMEATE WAT...

Page 4: ...M OUT PERM IN PERM IN 1 9 2 3 10 5 5 5 4 4 4 6 6 6 7 8 X GREEN TUBING BLACK TUBING BLACK BLACK BLACK TUBING BLACK B L A C K BLUE BLUE BLUE BLUE BLUE BLUE BLACK BLACK TUBING BLACK TUBING BLACK TUBING E4 E2 E1 E3 A A ITEM ITEM DESCRIPTION PART NUMBER 1 2 3 4 5 6 7 8 9 10 10 A B C D D1 D4 E1 E4 H1 H6 G1 G4 G1 G4 107021 107024 101011 210000 222019 152002 219002 307020 234010 134028 5 MICRON SEDIMENT F...

Page 5: ...M OUT PERM IN PERM IN 1 9 2 3 10 5 5 5 4 4 4 6 6 6 7 8 X GREEN TUBING BLACK TUBING BLACK BLACK BLACK TUBING BLACK B L A C K BLUE BLUE BLUE BLUE BLUE BLUE BLACK BLACK TUBING BLACK TUBING BLACK TUBING E4 E2 E1 E3 A A ITEM ITEM DESCRIPTION PART NUMBER 1 2 3 4 5 6 7 8 9 10 10 A B C D D1 D4 E1 E4 H1 H6 G1 G4 G1 G4 107021 107024 101011 210000 222019 152002 219002 307020 234010 134028 5 MICRON SEDIMENT F...

Page 6: ...mbrane Filter 3 61301605473 Flow Restrictor 750 ml 3 61301605471 5 Gal Storage tank 1 61301605449 Filter Sediment 5 micron 1 61301605447 Filter Carbon Block 5 micron 1 61301605450 Filter GAC KDF 1 61301605516 Filter Calcite 1 61301605476 Valve Check 1 2 Brass 2 61301605474 Valve Ball 1 2 Brass 1 61301605518 HS 200 Unit PM Kit 1 ...

Page 7: ...1 2 14 0000 EA 20 F231055 HEX NIPPLE BR 1 2MX1 4M REDUCR 1 0000 EA 21 F231095 CON BR 1 2CX1 2M 2 0000 EA 22 F231098 CON BR 1 2CX3 4M 1 0000 EA 23 F231152 ELB BR 1 2Cx3 8M 90 3 0000 EA 24 F231155 ELB BR 1 2CX1 2M 90 2 0000 EA 25 F231179 TEE BR 1 2C ALL 2 0000 EA 26 F231194 FTG ELBOW BR 3 4 F X 3 4 F 90 1 0000 EA 27 F231272 ADAPT BR BULKHEAD 1 2F 3 0000 EA 28 F234010 VALVE CHECK BR 1 2F 6 2 0000 EA ...

Page 8: ... WH 1 0000 PC 62 JG 481223 W 3 TGI PUSH IN FIXED ELBOW 3 8 TB X 3 8 NPT WH 1 0000 PC 63 MH 200WL 3 TGI MEMBRANE HOUSING WHITE SIDE PORT 1 8 NPT 3 0000 PC 64 MS1034 FTG MOUNTING SCREW 10X3 4 FOR 4000 4200 SERIES S 16 0000 EA 65 N O 4W FTG JACO COMPRESSION NUT1 4 NUT WHITE 6 0000 EA 66 NMSSS8C BOLT NUT HEX SS 8 32 12 0000 EA 67 PE 08 BI 0500FB TUB 1 4 INCH TUBE 500FTROLL BLUE 0 0160 ROLL 68 PE 08 BI...

Page 9: ...need to turn off incoming water source discard unscrew remaining filters and discard 3 Install new filters by removing yellow cap figure 3 on top and inserting each filter into corresponding element head Insure all filters are hand tight and listen for permeate pumps to begin pulsating check for leaks 4 Secure front panel A full one year supply of filters is supplied with system upon installation ...

Page 10: ...hut down incoming water flow to system Drain the tank of boiler feed water by performing a blow down on the boiler After tank has been completely drained disconnect the membranes by pressing in on the collets around the colored tubing figure 6 to the membrane and pull Each membrane should be removed one at a time insuring proper placement of tubing in corresponding color coded ports Re tighten fir...

Page 11: ...g or threading to pipe 6 For valves with Quick Connect tailpieces refer to Quick Connect Installation instructions below Quick Connect Installation Note To prevent damage to valve from excessive heat during soldering remove unions and gaskets from valve body prior to soldering 7 After soldering flush piping and install valve using filter washer on hot and cold water inlet and fiber washer on the m...

Page 12: ... Temperatures hot inlet 120 F 200 F 49 C 93 C cold inlet 40 F B5 F 4 C 29 C Hot Water Inlet to Outlet Differential Temperatwe 5 F 3 C 1170 M2 Temperature Out Field range 90 F 160 F 32 C 71 C adjustable Accurate within 3 F 1 7 C L1170 M2 Temperature Out Field range 60 F 120 F 16 C 49 C adjustable Accurate within 3 F 1 7 C Maximum Temperature 200 F 93 C Maximum Pressure 150psi 10 3 bar _ Approval CS...

Page 13: ...y debris H Flow from valve fluctuates H 1 Fluctuation in supply pressures H 2 Check valve filters blocked by debris Answer A 1 Check di_fferential temper ture betwe_ en hpt and cold supplies and outlet 10 F 5 6 C minimum required A 2 Reinstall valve with supplies connected to marked inlets A 3 Clean filters 8 1 Measure supply pressures and check against flow chart Look for restrictions in valve or...

Page 14: ...ial damages Including without llmltatlon lost profits or thecost of repairing or replacing other property which Is damaged If this product does not work properly othor costs resulling from labor charges delays vandalism negligence fouling caused by foreign materlal damage from adverse water conditions chemical or any other circumstances over which theCompany has no control This warranty shall be i...