background image

1

A BOX-FILTERPAK

PACK CARDBOARD SHEET WHT15.5 X 9.625 32 ECT GETIN

4.0000 EA

2

A BOX-HS333

PACK BOX 28X28X26 FORHS-333

1.0000 EA

3

A BOX-HS333-PLY

PACK HS333 PLYWOOD INSERT

1.0000 EA

4

A FOAM-HS333

PACK FOAM CORNER PADS FORHS333 UNIT

8.0000 EA

5

C2500W

RO  MOUNTING CLIP SINGLE2 1/2" WHITE

6.0000 EA

6

CI061208W

FTG 3/8 - 1/4 REDUCER WHITE

1.0000 EA

7

ERP-1000

PUMP AQUATEC PERMEATE PUMP UP TO 100 GPD/NON ELEC

3.0000 EA

8

F10-4-6-N-O

FTG JACO MALE CONNECTOR 1/4" NUT X 3/8" MNPT

3.0000 EA

9

F107021

SED-5M-Q SERIES Q/C-14"

4.0000 EA

10

F107024

KDF HS-333 Q-SERIES-14"

4.0000 EA

11

F107027

HOUSING-LID-Q SER-3/8"F-VLV HD

4.0000 EA

12

F110000

ROM - 100 GPD MEMBRANE

3.0000 EA

13

F125062

TEE-PL-M-RUN-3/8MPTX1/2C

1.0000 EA

14

F125089

ELB-1/4FQCX1/4MQC-PLASTICWHITE

12.0000 EA

15

F134015

RO CHECK VALVE FOR MANIFOLD

6.0000 EA

16

F219002

TANK PRESSURE (RP-5) 105

1.0000 EA

17

F222019

FLOW RESTRICTOR-750ML/M-STD

3.0000 EA

18

F231023

SLEEVE-DELRIN-1/2-PL

14.0000 EA

19

F231029

INSERT-BR-1/2

14.0000 EA

20

F231055

HEX NIPPLE-BR-1/2MX1/4M-REDUCR

1.0000 EA

21

F231095

CON-BR-1/2CX1/2M

2.0000 EA

22

F231098

CON-BR-1/2CX3/4M

1.0000 EA

23

F231152

ELB-BR-1/2Cx3/8M-90

3.0000 EA

24

F231155

ELB-BR-1/2CX1/2M-90

2.0000 EA

25

F231179

TEE-BR-1/2C ALL

2.0000 EA

26

F231194

FTG ELBOW BR 3/4"F X 3/4"F 90

1.0000 EA

27

F231272

ADAPT-BR-BULKHEAD-1/2F

3.0000 EA

28

F234010

VALVE-CHECK-BR-1/2F-#6

2.0000 EA

29

F234058

VALVE-BLENDING 1/2"NPT 60-120

1.0000 EA

30

F237002

BRACKET-SINGLE-Q SERIES-14 GA

1.0000 EA

31

F237023

FRAME-M200 SS BOX

1.0000 EA

32

F240024

CAP PLUG 8X- M200

3.0000 EA

33

F246002

INSERT 1/4-20

4.0000 EA

34

F246033

BOLT-DOME-1/4-20x1/2"L-PHIL-SS

2.0000 EA

35

F246081

NUT-1/4-20 HEX FINISH STAR LOC

4.0000 EA

36

F249019

LEG-GLIDE-1/4-20

4.0000 EA

37

F261008-NP

GAUGE 0-200 PRESSURE/TEMP2.5 CENTER BACK MOUNT NO

1.0000 EA

38

F264013

PLUG-NYLON-BLACK-2.5"

1.0000 EA

39

F299120

MANUAL-HS200

1.0000 EA

40

F299300

STICKER BOILER MATE

1.0000 EA

41

F299301

LABELS-KIT-INFO-M200-2-1/2X1/2

1.0000 EA

42

F299600

LABEL-MEMBRANE-GETINGE-GREEN#4

3.0000 EA

43

F299609

LABELS-KIT-FILT-#'S-HS20-41279

1.0000 EA

44

F299610

LABEL-GETINGE-BRINE & PERMEATE

3.0000 SET

570200 HS-200 PT BOM

Summary of Contents for HS-200 PT

Page 1: ...ent Increased reliability fewer equipment breakdowns due to boiler scaling Convenient quarterly maintenance intervals with economical PM packages available SPECIFICATIONS Provides 5 50 TDS output water from potable water sources up to 2000 TDS 250 ppm or 14 grains hardness PM package available separately Includes a year s supply of consumable components Watts Modernization Package HS 200 PT Revers...

Page 2: ...degrees F 50 90 psig 2000TDS 250ppm or 14 grains hardness Operation Once all service and output connections are made simply turn on cold water supply to the unit Maintenance Quarterly Replace pre filters items 1 2 3 8 Annually Replace membrane cartridges item 4 Replacement Parts PM Package Part 501020 PM package includes a 1 year supply of Items 1 2 3 4 8 Individual part numbers for component part...

Page 3: ...XIMUM 1200 PPM OR 500mg L NaCl 8 First year preventitive maintenance kit included P N 501020 9 CLEARANCE MINIMUM 18 SERVICE CLEARANCE ON SIDES D C MINIMUM 35 ON SIDE A 10 FLOOR DRAIN REQUIREMENTS MIN 1 2 DIA WITHIN 10 OF PROCESSING UNIT SOURCE OF SUPPLY PROCESSOR P N 570200 MFG Watts Pure Water Phoenix AZ USA 9 50 9 50 24 00 22 00 14 00 16 07 1 50 13 00 16 02 21 15 20 00 24 00 22 00 1 PERMEATE WAT...

Page 4: ...M OUT PERM IN PERM IN 1 9 2 3 10 5 5 5 4 4 4 6 6 6 7 8 X GREEN TUBING BLACK TUBING BLACK BLACK BLACK TUBING BLACK B L A C K BLUE BLUE BLUE BLUE BLUE BLUE BLACK BLACK TUBING BLACK TUBING BLACK TUBING E4 E2 E1 E3 A A ITEM ITEM DESCRIPTION PART NUMBER 1 2 3 4 5 6 7 8 9 10 10 A B C D D1 D4 E1 E4 H1 H6 G1 G4 G1 G4 107021 107024 101011 210000 222019 152002 219002 307020 234010 134028 5 MICRON SEDIMENT F...

Page 5: ...M OUT PERM IN PERM IN 1 9 2 3 10 5 5 5 4 4 4 6 6 6 7 8 X GREEN TUBING BLACK TUBING BLACK BLACK BLACK TUBING BLACK B L A C K BLUE BLUE BLUE BLUE BLUE BLUE BLACK BLACK TUBING BLACK TUBING BLACK TUBING E4 E2 E1 E3 A A ITEM ITEM DESCRIPTION PART NUMBER 1 2 3 4 5 6 7 8 9 10 10 A B C D D1 D4 E1 E4 H1 H6 G1 G4 G1 G4 107021 107024 101011 210000 222019 152002 219002 307020 234010 134028 5 MICRON SEDIMENT F...

Page 6: ...mbrane Filter 3 61301605473 Flow Restrictor 750 ml 3 61301605471 5 Gal Storage tank 1 61301605449 Filter Sediment 5 micron 1 61301605447 Filter Carbon Block 5 micron 1 61301605450 Filter GAC KDF 1 61301605516 Filter Calcite 1 61301605476 Valve Check 1 2 Brass 2 61301605474 Valve Ball 1 2 Brass 1 61301605518 HS 200 Unit PM Kit 1 ...

Page 7: ...1 2 14 0000 EA 20 F231055 HEX NIPPLE BR 1 2MX1 4M REDUCR 1 0000 EA 21 F231095 CON BR 1 2CX1 2M 2 0000 EA 22 F231098 CON BR 1 2CX3 4M 1 0000 EA 23 F231152 ELB BR 1 2Cx3 8M 90 3 0000 EA 24 F231155 ELB BR 1 2CX1 2M 90 2 0000 EA 25 F231179 TEE BR 1 2C ALL 2 0000 EA 26 F231194 FTG ELBOW BR 3 4 F X 3 4 F 90 1 0000 EA 27 F231272 ADAPT BR BULKHEAD 1 2F 3 0000 EA 28 F234010 VALVE CHECK BR 1 2F 6 2 0000 EA ...

Page 8: ... WH 1 0000 PC 62 JG 481223 W 3 TGI PUSH IN FIXED ELBOW 3 8 TB X 3 8 NPT WH 1 0000 PC 63 MH 200WL 3 TGI MEMBRANE HOUSING WHITE SIDE PORT 1 8 NPT 3 0000 PC 64 MS1034 FTG MOUNTING SCREW 10X3 4 FOR 4000 4200 SERIES S 16 0000 EA 65 N O 4W FTG JACO COMPRESSION NUT1 4 NUT WHITE 6 0000 EA 66 NMSSS8C BOLT NUT HEX SS 8 32 12 0000 EA 67 PE 08 BI 0500FB TUB 1 4 INCH TUBE 500FTROLL BLUE 0 0160 ROLL 68 PE 08 BI...

Page 9: ...need to turn off incoming water source discard unscrew remaining filters and discard 3 Install new filters by removing yellow cap figure 3 on top and inserting each filter into corresponding element head Insure all filters are hand tight and listen for permeate pumps to begin pulsating check for leaks 4 Secure front panel A full one year supply of filters is supplied with system upon installation ...

Page 10: ...hut down incoming water flow to system Drain the tank of boiler feed water by performing a blow down on the boiler After tank has been completely drained disconnect the membranes by pressing in on the collets around the colored tubing figure 6 to the membrane and pull Each membrane should be removed one at a time insuring proper placement of tubing in corresponding color coded ports Re tighten fir...

Page 11: ...g or threading to pipe 6 For valves with Quick Connect tailpieces refer to Quick Connect Installation instructions below Quick Connect Installation Note To prevent damage to valve from excessive heat during soldering remove unions and gaskets from valve body prior to soldering 7 After soldering flush piping and install valve using filter washer on hot and cold water inlet and fiber washer on the m...

Page 12: ... Temperatures hot inlet 120 F 200 F 49 C 93 C cold inlet 40 F B5 F 4 C 29 C Hot Water Inlet to Outlet Differential Temperatwe 5 F 3 C 1170 M2 Temperature Out Field range 90 F 160 F 32 C 71 C adjustable Accurate within 3 F 1 7 C L1170 M2 Temperature Out Field range 60 F 120 F 16 C 49 C adjustable Accurate within 3 F 1 7 C Maximum Temperature 200 F 93 C Maximum Pressure 150psi 10 3 bar _ Approval CS...

Page 13: ...y debris H Flow from valve fluctuates H 1 Fluctuation in supply pressures H 2 Check valve filters blocked by debris Answer A 1 Check di_fferential temper ture betwe_ en hpt and cold supplies and outlet 10 F 5 6 C minimum required A 2 Reinstall valve with supplies connected to marked inlets A 3 Clean filters 8 1 Measure supply pressures and check against flow chart Look for restrictions in valve or...

Page 14: ...ial damages Including without llmltatlon lost profits or thecost of repairing or replacing other property which Is damaged If this product does not work properly othor costs resulling from labor charges delays vandalism negligence fouling caused by foreign materlal damage from adverse water conditions chemical or any other circumstances over which theCompany has no control This warranty shall be i...

Reviews: