Arsenic (As) is a naturally occurring contaminant found in many ground waters. 

Arsenic in water has no color, taste or odor. It must be measured by an arsenic 

test kit or lab test.

Public water utilities must have their water tested for arsenic. You can obtain the 

results from your water utility contained with in your consumer confidence report. 

If you have your own well, you will need to have the water evaluated. The local 

health department or the state environmental health agency can provide a list of 

test kits or certified labs.

There are two forms of arsenic: pentavalent arsenic (also called As (V), As (+5)) 

and trivalent arsenic (also called As (III), As (+3)). In well water, arsenic may be 

pentavalent, trivalent, or a combination of both. Although both forms of arsenic are 

potentially hazardous to your health, trivalent arsenic is considered more harmful 

than pentavalent arsenic. 

RO systems are very effective at removing pentavalent arsenic. A free chlorine 

residual will rapidly convert trivalent arsenic to pentavalent arsenic. Other water 

treatment chemicals such as ozone and potassium permanganate will also change 

trivalent arsenic to pentavalent arsenic. A combined chlorine residual (also called 

chloramine) where it does convert trivalent arsenic to pentavalent arsenic, may 

not convert all the trivalent arsenic in to pentavalent arsenic. If you get your water 

from a public water utility, contact the utility to find out if free chlorine or combined 

chlorine is used in the water system.

This Watts reverse osmosis system is designed to remove up to 98% of pentavalent 

arsenic. It will not convert trivalent arsenic to pentavalent arsenic. Under laboratory 

standard  testing  conditions,  this  system  reduced  0.30  mg/L  (ppm)  pentavalent 

arsenic to under 0.010 mg/L (ppm) (the USEPA standard for drinking water). Actual 

performance of the system may vary depending on specific water quality conditions 

at the consumer’s installation. 

The RO membrane component of this reverse osmosis system must be maintained 

according to its recommended maintenance cycle. Specific component identification 

and  ordering  information  can  be  found  in  the  installation/operation  manual 

maintenance section.

Arsenic Fact Sheet

Summary of Contents for GTS450S

Page 1: ...instructions or operating parameters may lead to the product s failure Refer to enclosed warranty for operating parameters to ensure proper use with your water supply Watts 2010 M WQP GTS 1041 INSTALL...

Page 2: ...at traps sediment and other particulate matter like dirt silt and rust which affect the taste and appearance of your water Stage 2 and 3 Carbon filters recommended change 6 months Stage 3 Only on the...

Page 3: ...a Hole for the Faucet in a Stainless Steel Sink 6 Adapt a Valve Installation 6 Typical RO Faucet Installation 7 Drain Saddle Installation 8 System Drain Connection 8 Green Tube Connection Feed Water 9...

Page 4: ...37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 85 psi 6 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity...

Page 5: ...the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a permanent leak proof seal Pull on the tube to check that i...

Page 6: ...nd an adjustable wrench to punch the hole in the sink Step 5 If mounting faucet to a Stainless Steel Sink you will need a Hole Punch The faucet opening should be centered between the back splash and t...

Page 7: ...using Attached to the polishing filter is a 3 8 quick connect elbow fitting Attach the open end of the 3 8 blue tubing from the RO faucet to the 3 8 quick connect elbow on the polishing filter With No...

Page 8: ...the drain saddle kit Insert the red tube into the opening in the drain saddle and hand tighten the black nut and add 1 4 turn with a wrench The 3 8 drain tube must be as SHORT and STRAIGHT as possibl...

Page 9: ...on top of the tank Tank Valve Installation Metal Tank Tank Valve Installation Plastic Tank Thread the plastic valve onto the tank fitting Do not over tighten or the valve could crack Step 1 Step 2 Mak...

Page 10: ...king Open the RO faucet and leave it open until water begins to trickle out it will come out slowly Step 4 Turn on the incoming cold water at the angle stop valve Open the needle valve on the brass Ad...

Page 11: ...k O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Before re installing the f...

Page 12: ...turning the adapt a valve clockwise until it stops Keep the RO faucet open until the storage tank is completely drained Open the membrane housing and re install the RO membrane while making sure not t...

Page 13: ...he needle valve on the adapt a valve clockwise until it stops Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 2 Removing the membrane Installing the membran...

Page 14: ...an be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap Tip When water from the RO faucet slows to a trickle with the faucet...

Page 15: ...pty tank pressure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tubing and straighten or repair as necessary vent hole or noise from in drain line Straighten all d...

Page 16: ...Page 16 5 Stage Reverse Osmosis System Third Filter Bowl on GTS550S System Only...

Page 17: ...emperature Maximum 100 F 40 5 C Minimum 40 4 4 3 Operating Water Pressure Maximum 100 psi 7 0kg cm2 Minimum 40 psi 2 8kg cm2 4 pH 2 to 11 5 Maximum iron present in incoming feed water supply must be l...

Page 18: ...senic to pentavalent arsenic Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called...

Page 19: ...urchase __________ Date of Install ___________ Installed by __________________ NOTES Date 1st stage Sediment 6 months 2 nd stage Carbon 6 months 3rd stage Carbon 6 months W500S Only Final Filter Carbo...

Page 20: ...ng water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do...

Reviews: